noise f1128e807a Record decision to keep 48.0V discharge floor (improvement #3)
Reviewed the cutoff/stop-discharge floor; deliberately kept at 48.0V (3.00
V/cell) for cycle-life margin. Lowering to 46-47V unlocks only a few % of LFP
capacity and isn't worth deeper cycling on this large, non-capacity-constrained
bank. Comment only; no value change.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 12:28:44 -04:00
2026-04-24 16:34:10 -04:00
2026-06-23 18:49:47 -04:00
2026-05-01 16:56:37 -04:00
2026-04-24 16:34:10 -04:00
Description
No description provided
64 MiB
Languages
Python 91.7%
Shell 7.2%
Dockerfile 1.1%