Files
shaggy-solar/LVX6048/2026-04-26.md
2026-04-26 08:49:05 -04:00

4.8 KiB
Raw Permalink Blame History

2026-04-26 — inverter MQTT entity cleanup

Mirrors the eg4battery cleanup landed earlier today. Same set of issues (no precision hints, missing state_class, dead/misleading entities) plus a couple of powermon-specific quirks.

What changed

  1. New patch (g) — outputformats/hass.py. Rewrites powermon's HA discovery-payload assembly so:

    • suggested_display_precision is set per unit (V/A → 1 dp, W/VA/% → 0, °C → 0, Hz → 1, Ah → 1, etc.). Frontend now renders 52.5 V instead of 52 V.
    • state_class: measurement is set by default for numeric sensors that don't have an explicit class. Required for HA's long-term statistics + Energy dashboard wiring; previously only ac_output_active_power had it.
    • last_reset: <datetime> removed from every payload. HA spec allows it only on state_class: total cumulative counters; on measurement sensors HA warns and ignores. Upstream emits it unconditionally.
    • force_update: "true" removed from default. Forced HA to record every state publish even when value unchanged; bloats DB for slow-changing fields (battery V, currents, temps).
  2. Patch (a) tweak. "DC-AC power direction""DC AC power direction". Causes the HA entity_id to become dc_ac_power_direction (underscore, conforming) rather than the previous dc-ac_power_direction (hyphen, non-conforming).

  3. excl_filter added to GS command in both powermon.yaml and powermon2.yaml:

    excl_filter: '^(battery_voltage_from_scc.*|mppt2_.*|setting_value_configuration_state)$'
    

    Drops 7 always-zero / always-misleading fields:

    • battery_voltage_from_scc, battery_voltage_from_scc2 — no separate SCC bus on this hardware
    • mppt2_input_voltage, mppt2_input_power, mppt2_charger_temperature, mppt2_charger_status — nothing connected to PV input #2; would auto- resurrect if MPPT2 is ever wired
    • setting_value_configuration_state — internal config-write echo, no operational value
    • kept: parallel_instance_number (will become useful when parallel comms work) and load_connection (will become live when output is enabled)
  4. tmp/lvx-purge-orphans new tool. Same shape as eg4-purge-orphans: publishes empty retained payloads to the deprecated discovery-config topics so HA forgets the orphans the broker still has cached. Idempotent. paho-mqtt 1.x and 2.x compatible.

Net effect

Metric Before After Delta
Published state topics per inverter 29 23 21 %
Total stack (2 inverters) 58 46 12 (16 orphans purged)
Voltages displayed at integer precision many 0 now show 1 dp
Sensors qualified for HA long-term stats 1 all numeric proper trends + Energy dashboard wiring
Bogus last_reset warnings on HA startup 58 0 clean log
Recorder rows per slow-changing entity / 24h ~17 k only on change DB bloat reduced

Files touched

A  powermon-patches/hass.py            (new patch g)
M  powermon-patches/pi18.py            (patch a tweak: "DC-AC" → "DC AC" in field name)
M  powermon-patches/README.md          (document patch g)
M  install.sh                          (copy hass.py during install)
M  Install.md                          (§5(g) doc)
A  tmp/lvx-purge-orphans               (one-shot orphan cleanup)
M  config/powermon/powermon.yaml       (excl_filter added to GS; password placeholder restored)
M  config/powermon/powermon2.yaml      (same)
A  2026-04-26.md                       (this file)

How to verify

# Discovery configs now include precision hint + state_class
mosquitto_sub -h <broker> -u mqtt -P <pass> \
    -t 'homeassistant/sensor/lvx6048_1_battery_voltage/config' -W 5 -v
# Expect: ..., "state_class": "measurement", "suggested_display_precision": 1, ...
# Expect: NO "last_reset" or "force_update" fields

# Renamed entity surfaces with underscore
mosquitto_sub -h <broker> -u mqtt -P <pass> \
    -t 'homeassistant/sensor/lvx6048_1_dc_ac_power_direction/state' -W 5 -v
# Expect: state value (e.g. "donothing")

# Verify dropped fields are gone
mosquitto_sub -h <broker> -u mqtt -P <pass> \
    -t 'homeassistant/sensor/+/state' -W 12 -v \
  | grep -E 'lvx6048_._(battery_voltage_from_scc|mppt2|setting_value_configuration|dc-ac)'
# Expect: zero matches

Rollback

# Revert source
git checkout HEAD~1 -- LVX6048/

# Re-apply old patches to live install (the unpatched hass.py comes from pip)
cd LVX6048 && ./install.sh   # idempotent, will copy old hass.py back

sudo systemctl restart powermon.service powermon2.service