# TDMCSVImport Documentation
## 1. Purpose
The `TDMCSVImport` class provides logic for importing sensor configuration data from a CSV file into the systems internal `SensorData` representation. It parses CSV rows (one per sensor) using a predefined set of column labels, maps string values to strongly-typed enums and properties, and constructs a fully initialized `SensorData` object. This module serves as the ingestion layer for legacy TDM (Test Data Manager) CSV exports, supporting a wide range of sensor types (full/half bridge, voltage, IRTRACC, potentiometers, angular rate sensors), calibration parameters, zeroing methods, filtering options, and Toyota-specific calculations. It is part of the `DTS.SensorDB.TDM` namespace and is used in contexts where CSV-based sensor metadata must be ingested into the sensor database.
## 2. Public Interface
### `public static TAGS LabelToTag(string label)`
- **Signature**: `public static TAGS LabelToTag(string label)`
- **Behavior**: Converts a CSV column header string (e.g., `"Serial No"`, `"Filter Type"`) into the corresponding `TAGS` enum value. Throws `NotSupportedException` if the label is unrecognized.
- **Note**: This is the only public method in the class.
### Nested Types (used internally)
The following enums are declared as `private` but are essential to understanding the mapping logic:
- **`MeasurementTypes`**: Internal enum representing sensor measurement types (e.g., `MEASTYPE_FULLBRIDGE`, `MEASTYPE_IRTRACC`, `MEASTYPE_ARS_ANGLE`). Used to determine bridge type and calibration behavior.
- **`FilterTypes`**: Internal enum representing filter types (e.g., `FILTERTYPE_CFC60`, `FILTERTYPE_FIR100`, `FILTERTYPE_USEFREQ`). Maps to `FilterClassType` or `FilterClass` constructor overloads.
- **`ZeroMethods`**: Internal enum representing zeroing strategies (`ZMETHOD_PREZERO`, `ZMETHOD_AVGTIME`, `ZMETHOD_EQUALS0MV`).
- **`TAGS`**: Public enum listing all supported CSV column labels (e.g., `SENSOR_CSV_LABEL_SERIAL_NO`, `SENSOR_CSV_LABEL_FILTER_TYPE`). Includes an `UNKNOWN` entry for unrecognized columns.
### Private Helper Methods (not part of public interface, but documented for completeness)
- `private static MeasurementTypes LabelToMeasurementType(string label)`
Converts CSV string labels (e.g., `"Full Bridge"`) to `MeasurementTypes`.
- `private static string MeasurementTypeToLabel(MeasurementTypes mt)`
Converts `MeasurementTypes` back to CSV labels.
- `private static string TagToLabel(TAGS tag)`
Converts `TAGS` enum to CSV column header strings.
### `public static DTS.SensorDB.SensorData GetSensor(...)`
- **Signature**:
```csharp
public static DTS.SensorDB.SensorData GetSensor(
string[] tokens,
TAGS[] tagOrder,
ref List<string> errors,
Dictionary<string, string> sensorTypeToDimension)
```
- **Behavior**: Parses a single CSV row (`tokens`) using the column order specified in `tagOrder`. Populates a new `SensorData` instance with values from the row. Errors encountered during parsing (e.g., invalid numbers, unrecognized labels) are appended to the `errors` list. The `sensorTypeToDimension` dictionary maps sensor type strings (e.g., `"Accelerometer"`) to physical dimension strings (e.g., `"Acceleration"`), which are used to set `sd.PhysicalDimension`.
Key behaviors:
- Trims and normalizes string tokens (removes leading `=`, surrounding quotes).
- Handles date parsing for `"Calibration Date"` (supports `/` or `-` separators).
- Defaults excitation voltage to 5V if `0` is provided in CSV.
- Sets `sd.UUID = sd.SerialNumber`.
- Applies default values for missing `Capacity` (→ 1) and `DisplayUnit` (→ `"g"`), logging warnings.
- For `MEASTYPE_IRTRACC`, sets `NonLinear = true` and configures non-linear calibration parameters.
- Maps `FilterTypes.FILTERTYPE_FIR100` to `CFC180` with a warning (unsupported).
- Stores Toyota calculation strings (`calc1`, `calc2`, `calc3`) concatenated into `sd.UserValue3`.
## 3. Invariants
- **`SensorData` must always be initialized**: A new `SensorData` and `SensorCalibration` are created unconditionally at the start of `GetSensor`.
- **`Bridge` type is always set**: Based on `MeasurementType`, `sd.Bridge` is assigned one of `FullBridge`, `HalfBridge_SigPlus`, or (implicitly) defaults to one of these.
- **`Calibration.Records.Records[0]` is always populated**: The first calibration record is always initialized and updated with sensitivity, units, and other fields.
- **`DisplayUnit` and `EngineeringUnits` are always set**: If missing in CSV, defaults to `"g"` and applies to all calibration records (per FB16398).
- **`Capacity` is always ≥ 1**: If `Capacity < 1`, it is set to `1` and a warning is logged.
- **`UUID` is always set to `SerialNumber`**: `sd.UUID = sd.SerialNumber` is applied unconditionally.
- **Filter is always assigned**: Even if `FILTERTYPE_FIR100` is unsupported, a fallback filter (`CFC180`) is assigned.
- **`Invert`, `Shunt`, `RemoveOffset` are always set**: Boolean fields default to `false` if parsing fails, but are never left uninitialized.
## 4. Dependencies
### Module Dependencies (from `using` directives and type references):
- `DTS.Common.Classes.Sensors` — Provides `SensorData`, `SensorCalibration`, `SensorConstants`.
- `DTS.Common.DAS.Concepts` — Provides `ExcitationVoltageOptions`, `Test.Module.Channel.Sensor.GetExcitationVoltageEnumFromMagnitude`.
- `DTS.Common.Enums`, `DTS.Common.Enums.Sensors` — Provides `NonLinearStyles`, `ShuntMode`, `ZeroMethodType`, `SensorConstants.SensUnits`.
- `System`, `System.Collections.Generic`, `System.Linq`, `System.Text` — Standard .NET types.
### External Dependencies (inferred):
- `DTS.SensorDB.SensorData` — The primary output type; implies a dependency on the `DTS.SensorDB` assembly.
- `FilterClass` and `FilterClassType` — Used to instantiate filters; implies a dependency on a filtering subsystem.
- `InitialOffsets`, `InitialOffset` — Used for zeroing; implies a dependency on zeroing-related types.
### Inbound Dependencies:
- This module is used by callers that provide CSV rows and a `sensorTypeToDimension` mapping (likely derived from a sensor type catalog).
- Requires `SensorData` and related types to be fully defined and compatible with the properties being set.
### Outbound Dependencies:
- None explicitly declared beyond the above; this module is a leaf in the data ingestion pipeline.
## 5. Gotchas
- **`FILTERTYPE_FIR100` is unsupported**: The code maps it to `CFC180` and logs a warning, but this may cause unexpected filter behavior if FIR100 was intended.
- **Zeroing parameters are only applied to `Methods[0]`**: `ZeroTimeStartMsec`, `ZeroTimeEndMsec`, and `ZeroInitialEU` only populate the first zero method (`Methods[0]`). If multiple zero methods are expected, this may be incomplete.
- **`Range_3` is commented out**: The `SENSOR_CSV_LABEL_RANGE_3` case is present but commented out; it does not set `sd.Capacity` despite the comment suggesting it might.
- **Excitation voltage `0` is treated as 5V**: This is explicitly handled as a special case for “Voltage Insertion” mode, but may be non-obvious to callers.
- **Date parsing is fragile**: Supports only `MM/DD/YYYY` or `YYYY-MM-DD` formats; other formats (e.g., `DD/MM/YYYY`) will fail unless the CSV uses unambiguous separators or ISO 8601.
- **`UNKNOWN` tag is silently ignored**: Any CSV column not in `TAGS` is mapped to `TAGS.UNKNOWN` and skipped.
- **`UserValue1`/`UserValue2`/`UserValue3` are repurposed**: `JCODE` → `UserValue1`, `CODE` → `UserValue2`, and concatenated Toyota calcs → `UserValue3`. This may conflict with other uses of these fields elsewhere.
- **`SensorType` validation is dictionary-dependent**: If `sensorTypeToDimension` does not contain the provided sensor type string, an error is logged but `PhysicalDimension` remains unset (defaulting to `null` or empty).
- **No validation of `SensitivityUnits` consistency**: The code sets `IsProportional` based on units, but does not validate whether the combination of `SensitivityUnits`, `BridgeType`, and `MeasurementType` is physically meaningful.
- **`RemoveOffset` parsing is case-insensitive but not robust**: Accepts `"1"/"T"/"Y"` and `"0"/"F"/"N"` but not `"true"/"false"` or `"yes"/"no"` explicitly.
- **`Invert` parsing is case-insensitive but limited**: Accepts `"0"/"F"/"N"` and `"1"/"Y"/"T"` but not `"true"/"false"`.
None identified beyond those listed above.