Files
DP44/docs/ai/DataPRO/IService/Classes/Diagnostics.md
2026-04-17 14:55:32 -04:00

5.7 KiB

source_files, generated_at, model, schema_version, sha256
source_files generated_at model schema_version sha256
DataPRO/IService/Classes/Diagnostics/OptimizationValues.cs
DataPRO/IService/Classes/Diagnostics/DiagnosticActions.cs
DataPRO/IService/Classes/Diagnostics/DiagnosticsResultActions.cs
DataPRO/IService/Classes/Diagnostics/DiagnosticsResult.cs
2026-04-17T15:38:51.449636+00:00 zai-org/GLM-5-FP8 1 34ce6d811e6f9b1a

Diagnostics Module Documentation

1. Purpose

This module provides data structures and operations for managing diagnostic tests and results for Data Acquisition System (DAS) channels. It enables pre-recording validation of sensor configurations by measuring excitation voltages, offsets, noise floors, shunt deflections, bridge resistance, and squib firing characteristics. The module bridges in-memory diagnostic state with persistent database storage, supporting analog input channels, digital input channels, and output squib channels.


2. Public Interface

OptimizationValues (Class)

Namespace: DTS.DASLib.Service.Classes.Diagnostics
Implements: IOptimizationValues

Property Type Description
TransferSpeed float Gets or sets the transfer speed value.

DiagnosticsActions (Class)

Namespace: DTS.DASLib.Service
Implements: IDiagnosticActions

Holds instructions for diagnosing a single DAS channel.

Properties

Property Type Default Description
DASChannelNumber int 0 The DAS channel number for these diagnostic instructions.
MeasureExcitation bool false Whether to measure excitation voltage applied to the sensor.
MeasureOffset bool false Whether to measure the sensor's offset from zero.
CheckDigitalState bool false Whether to check open/closed/low/high state of a digital input channel.
MeasureInternalOffset bool false Whether to measure internal offset.
RemoveOffset bool false Whether firmware should compensate for sensor offset.
MeasureNoise bool false Whether to measure noise floor as percentage of full scale.
PerformShuntCheck bool false Whether to perform an emulated shunt check.
SquibFireCheck bool false Whether to run a squib fire check on the channel.
PerformVoltageInsertCheck bool false Whether to perform a voltage insertion gain check (SLICE Pro).
PerformCalSignalCheck bool false Whether to perform a calibration signal check.
MeasureBridgeResistance bool false Whether to measure the resistance of the bridge.

Methods

public DiagnosticsActions()

Initializes a new instance with all diagnostic actions disabled and DASChannelNumber set to 0.

public bool AllActionsDisabled()

Returns true if all diagnostic actions are disabled; otherwise false.

public static void SetChannelDiagnosticActions(IDASCommunication unit, IDiagnosticActions[] actions, bool setInDb)

Assigns the diagnostic actions array to unit.ChannelDiagnostics. If setInDb is true and the database is connected, clears all existing diagnostic actions for the unit and inserts the new actions into the database.


DiagnosticsResultActions (Static Class)

Namespace: DTS.DASLib.Service.Classes.Diagnostics

Provides static methods for managing diagnostic results on DAS units.

Methods

public static void ClearChannelDiagnosticsResults(IDASCommunication unit, bool bClearDb = true)

Clears unit.ChannelDiagnosticsResults and unit.ChannelDiagnostics by initializing them to empty arrays. If bClearDb is true and the database is connected, clears existing diagnostics from the database for the unit.

public static void SetChannelDiagnosticsResults(IDASCommunication unit, IDiagnosticResult[] results, bool setInDb)

Assigns results to unit.ChannelDiagnosticsResults. If setInDb is true and the database is connected, iterates through results and inserts them into the database based on channel type:

  • AnalogInputDASChannel with DigitalInputChannel == trueInsertDiagnosticsResultDigital
  • AnalogInputDASChannel with DigitalInputChannel == falseInsertDiagnosticsResultAnalog
  • OutputSquibChannelInsertDiagnosticsResultsSquib

DiagnosticsResult (Class)

Namespace: DTS.DASLib.Service
Implements: IDiagnosticResult

Holds diagnostic results for a single DAS channel.

Key Properties

Property Type Default Description
DASChannelNumber int The channel number from which diagnostics are returned.
EventNumber int The event number this diagnostic is relevant for.
ScalefactorMilliVoltsPerADC double 1 Scale factor to convert raw ADC values to millivolts.
ScalefactorEngineeringUnitsPerADC double 1 Scale factor to convert ADC values to engineering units.
ExpectedExcitationMilliVolts double Factory excitation value (mandatory).
MeasuredExcitationMilliVolts double? Measured excitation voltage in mV.
NegativeExcitation bool Flag indicating if measured excitation was negative.
MeasuredOffsetMilliVolts double? Sensor offset from zero in mV.
MeasuredInternalOffsetMilliVolts double? Measured internal offset in mV.
AutoZeroPercentDeviation double? Deviation from zero during auto-zero (stored as absolute value).
FinalOffsetADC short? Offset remaining after offset removal.
RemovedOffsetADC int? Amount of offset removed.
`RemovedInternalOffsetADC