5.7 KiB
source_files, generated_at, model, schema_version, sha256
| source_files | generated_at | model | schema_version | sha256 | ||||
|---|---|---|---|---|---|---|---|---|
|
2026-04-17T15:38:51.449636+00:00 | zai-org/GLM-5-FP8 | 1 | 34ce6d811e6f9b1a |
Diagnostics Module Documentation
1. Purpose
This module provides data structures and operations for managing diagnostic tests and results for Data Acquisition System (DAS) channels. It enables pre-recording validation of sensor configurations by measuring excitation voltages, offsets, noise floors, shunt deflections, bridge resistance, and squib firing characteristics. The module bridges in-memory diagnostic state with persistent database storage, supporting analog input channels, digital input channels, and output squib channels.
2. Public Interface
OptimizationValues (Class)
Namespace: DTS.DASLib.Service.Classes.Diagnostics
Implements: IOptimizationValues
| Property | Type | Description |
|---|---|---|
TransferSpeed |
float |
Gets or sets the transfer speed value. |
DiagnosticsActions (Class)
Namespace: DTS.DASLib.Service
Implements: IDiagnosticActions
Holds instructions for diagnosing a single DAS channel.
Properties
| Property | Type | Default | Description |
|---|---|---|---|
DASChannelNumber |
int |
0 |
The DAS channel number for these diagnostic instructions. |
MeasureExcitation |
bool |
false |
Whether to measure excitation voltage applied to the sensor. |
MeasureOffset |
bool |
false |
Whether to measure the sensor's offset from zero. |
CheckDigitalState |
bool |
false |
Whether to check open/closed/low/high state of a digital input channel. |
MeasureInternalOffset |
bool |
false |
Whether to measure internal offset. |
RemoveOffset |
bool |
false |
Whether firmware should compensate for sensor offset. |
MeasureNoise |
bool |
false |
Whether to measure noise floor as percentage of full scale. |
PerformShuntCheck |
bool |
false |
Whether to perform an emulated shunt check. |
SquibFireCheck |
bool |
false |
Whether to run a squib fire check on the channel. |
PerformVoltageInsertCheck |
bool |
false |
Whether to perform a voltage insertion gain check (SLICE Pro). |
PerformCalSignalCheck |
bool |
false |
Whether to perform a calibration signal check. |
MeasureBridgeResistance |
bool |
false |
Whether to measure the resistance of the bridge. |
Methods
public DiagnosticsActions()
Initializes a new instance with all diagnostic actions disabled and DASChannelNumber set to 0.
public bool AllActionsDisabled()
Returns true if all diagnostic actions are disabled; otherwise false.
public static void SetChannelDiagnosticActions(IDASCommunication unit, IDiagnosticActions[] actions, bool setInDb)
Assigns the diagnostic actions array to unit.ChannelDiagnostics. If setInDb is true and the database is connected, clears all existing diagnostic actions for the unit and inserts the new actions into the database.
DiagnosticsResultActions (Static Class)
Namespace: DTS.DASLib.Service.Classes.Diagnostics
Provides static methods for managing diagnostic results on DAS units.
Methods
public static void ClearChannelDiagnosticsResults(IDASCommunication unit, bool bClearDb = true)
Clears unit.ChannelDiagnosticsResults and unit.ChannelDiagnostics by initializing them to empty arrays. If bClearDb is true and the database is connected, clears existing diagnostics from the database for the unit.
public static void SetChannelDiagnosticsResults(IDASCommunication unit, IDiagnosticResult[] results, bool setInDb)
Assigns results to unit.ChannelDiagnosticsResults. If setInDb is true and the database is connected, iterates through results and inserts them into the database based on channel type:
AnalogInputDASChannelwithDigitalInputChannel == true→InsertDiagnosticsResultDigitalAnalogInputDASChannelwithDigitalInputChannel == false→InsertDiagnosticsResultAnalogOutputSquibChannel→InsertDiagnosticsResultsSquib
DiagnosticsResult (Class)
Namespace: DTS.DASLib.Service
Implements: IDiagnosticResult
Holds diagnostic results for a single DAS channel.
Key Properties
| Property | Type | Default | Description |
|---|---|---|---|
DASChannelNumber |
int |
— | The channel number from which diagnostics are returned. |
EventNumber |
int |
— | The event number this diagnostic is relevant for. |
ScalefactorMilliVoltsPerADC |
double |
1 |
Scale factor to convert raw ADC values to millivolts. |
ScalefactorEngineeringUnitsPerADC |
double |
1 |
Scale factor to convert ADC values to engineering units. |
ExpectedExcitationMilliVolts |
double |
— | Factory excitation value (mandatory). |
MeasuredExcitationMilliVolts |
double? |
— | Measured excitation voltage in mV. |
NegativeExcitation |
bool |
— | Flag indicating if measured excitation was negative. |
MeasuredOffsetMilliVolts |
double? |
— | Sensor offset from zero in mV. |
MeasuredInternalOffsetMilliVolts |
double? |
— | Measured internal offset in mV. |
AutoZeroPercentDeviation |
double? |
— | Deviation from zero during auto-zero (stored as absolute value). |
FinalOffsetADC |
short? |
— | Offset remaining after offset removal. |
RemovedOffsetADC |
int? |
— | Amount of offset removed. |
| `RemovedInternalOffsetADC |