# LVX6048 settings profile — EG4 LifePower4 v2 LiFePO4 bank, open-loop.
#
# Designed for: 3× EG4 LP4 v2 100 Ah in parallel (300 Ah, ~15.4 kWh).
# Apply identically to both inverters in a parallel pair:
# sudo systemctl stop powermon.service powermon2.service
# ./flash.py apply --device /dev/lvx6048-1 --profile profiles/eg4-lp4-v2.yaml --confirm
# ./flash.py apply --device /dev/lvx6048-2 --profile profiles/eg4-lp4-v2.yaml --confirm
# sudo systemctl start powermon.service powermon2.service
# ./flash.py compare --device-a /dev/lvx6048-1 --device-b /dev/lvx6048-2
# ./flash.py sync-check --device-a /dev/lvx6048-1 --device-b /dev/lvx6048-2
#
# Voltage rationale (16S LFP, 3.2 V/cell nominal = 51.2 V pack):
# bulk 56.4 V = 3.525 V/cell — long-life sweet spot for LFP
# float 54.0 V = 3.375 V/cell — rest near mid-knee, avoid sitting on the top
# stop_charge 54.0 V — grid charges only to ~mid-knee; solar handles the bulk top-off
# stop_dis 48.0 V = 3.000 V/cell — soft "switch to grid" point
# cutoff 48.0 V = 3.000 V/cell — inverter hard shutdown floor (BMS still protects below)
# Conservative off-grid policy: keep grid as a soft top-up, let solar do the bulk work.
#
# Current rationale (300 Ah bank):
# 60 A/unit × 2 units = 120 A combined ≈ 0.4 C — well under bank's continuous spec
# 30 A/unit MUCHGC keeps grid-charging conservative (60 A combined)
# enum: AGM | FLOODED | USER
# USER required to enable the per-cell custom voltages below.
battery_type: USER
# V 40.0..48.0 — hard shutdown; must be < stop_discharge_voltage.
cutoff_voltage: 48.0
# V 44.0..51.0 — switch battery→grid below this (pair: stop_charge_voltage).
stop_discharge_voltage: 48.0
# V 0 (=Full) or 48.0..58.0 — switch grid→battery above this. 0 = let bulk define.
stop_charge_voltage: 54.0
# V 48.0..58.4 — CC→CV transition (pair: float_voltage; must be >= float_voltage).
bulk_voltage: 56.4
# V 48.0..58.4 — held while on grid (pair: bulk_voltage; must be <= bulk_voltage).
float_voltage: 54.0
# A 10,20,30,40,50,60,70,80 — combined solar+AC cap, per unit.
max_charging_current: 60
# A 2,10,20,30,40,50,60,70,80 — grid-side cap, per unit.
max_utility_charging_current: 30
# enum: solar_utility_battery | solar_battery_utility
output_source_priority: solar_battery_utility
# enum: solar_first | solar_and_utility | solar_only
charger_priority: solar_first
# enum: battery_load_utility_ac | load_battery_utility
solar_power_priority: battery_load_utility_ac
# enum: enabled | disabled (PEI/PDI)
grid_tie: disabled