# 2026-04-28 — bulletproof recovery + FWS / fault polling + EG4 discovery refresh Mostly resilience work today, prompted by waking up to find both powermon services inactive and no PV / battery data flowing from the inverters since ~06:11. Root-caused, recovered, and hardened the failure mode so it can't strand the stack again. While in there: closed two related polling gaps (faults weren't being captured at all, and EG4 discovery configs had fallen out of the broker — InfluxDB exporter had stopped seeing pack data). ## What happened 1. **Morning incident: powermon offline since 06:11.** udev fired the resolver during what looks like a sunrise cold-start window — both inverters were briefly unresponsive on USB-HID (`/dev/hidraw0` returned no PI18 reply; `/dev/hidraw1` returned 22 zero bytes for the serial query). Resolver hit its 10 s internal retry, gave up, exited with code 2. Powermon services had `Requires=lvx-resolve-links` so systemd refused to start them, and there was no retry path — stack stayed dead until manual intervention ~10 h later. 2. **Recovery.** Re-ran the resolver manually; both inverters responded normally on the second attempt. Started powermon services; PV voltages (305.2 V / 307.2 V), battery voltages (54.0 V), and all the usual telemetry flowed back within seconds. 3. **Bulletproofing the resolver path.** Three coordinated changes so a transient morning blip can't latch the whole stack offline: a. **Resolver → always-exit-0.** Best-effort policy: write whatever symlinks it can resolve, log warnings for the missing ones, always return success. Only-relink-on-change semantics so a no-op timer-driven run doesn't churn the symlinks. When symlinks *do* move (post-power-cycle), resolver auto-restarts powermon so its open hidraw fds re-bind. b. **`Wants=` instead of `Requires=`** on both powermon services. Resolver failure no longer propagates as "permanently failed" to dependent units. Powermon's own `Restart=always` handles the retry loop until `/dev/lvx6048-{1,2}` appear. c. **Periodic systemd timer** for the resolver (`lvx-resolve-links.timer`) — `OnBootSec=2min`, `OnUnitActiveSec=5min`. Belt-and-suspenders against any hot-plug case where udev didn't fire (stuck-USB scenario like this morning's). d. **`StartLimitIntervalSec=0`** on both powermon services — disables systemd's default "stop trying after 5 fails in 10 s" rate-limiter, so the retry loop continues indefinitely until success. Worst-case data gap is now ~2 min (timer cycle + couple polls) vs. the previous "until a human notices and runs systemctl restart". 4. **FWS fault polling added to powermon.** A separate gap surfaced during the morning's troubleshooting: front-panel showed a "32" indicator, and we discovered our `powermon.yaml` was polling `GS / MOD / PIRI / ET` only — no `FWS`. Faults / warnings weren't reaching MQTT at all. Added FWS (every 30 s) to both inverter configs. 5. **Defensive FWS fault-code decoder.** Same shape as the MOD `06`/`07` crashes from earlier in the week — an unknown fault code would `KeyError` and crash powermon. Pre-populated the OPTION dict with placeholder labels for codes 00–99, then layered the known names on top. Future unknown codes show as `"Fault 32"` rather than crashing. Also unblocks adding the four PI18 setters (PE / PD / POPM / PF) to the shim later — same pattern. 6. **About the LCD's "32".** Direct FWS queries to both units returned `fault_code=No fault` while `pv_loss_warning=enabled`. The LCD was most likely showing the PV-loss warning code (no F/W prefix on this firmware's display), correlating with the cold-start window. Not a real fault — but worth re-confirming the LCD format next time so we know whether 32-with-prefix is a thing on this hardware. 7. **EG4 lifepower discovery configs vanished.** Independent finding: when checking why `lvx6048_*_fault_code` wasn't appearing in HA, I noticed zero retained `homeassistant/sensor/lifepower4_*/config` topics on the broker. HA had cached entity registrations and was showing live state, but the canonical discovery configs were gone — likely cleared by an earlier `eg4-purge-orphans` invocation or broker retention loss. InfluxDB exporter relies on those configs to know what entities to publish, so pack voltages / SoCs had stopped reaching InfluxDB. Fix: `systemctl restart eg4-battery.service`. Daemon re-publishes all 207 retained discovery configs at startup (3 packs × ~69 entities). HA refreshes its registry, InfluxDB resumes capturing. ## Net effect | Layer | Before | After | |---|---|---| | Morning-blip recovery | manual `systemctl restart` (~10 h gap) | automatic ~2 min gap | | Resolver exit on missing serial | code 2 (systemd marks unit failed) | always 0 (best-effort) | | Resolver runs | only on udev hot-plug | + every 5 min via timer | | Powermon ↔ resolver coupling | `Requires=` (failure cascades) | `Wants=` (independent retry) | | Powermon retry budget | ~5 attempts (default StartLimit) | unbounded (`StartLimitIntervalSec=0`) | | Fault-code → MQTT | not polled | FWS every 30 s | | Unknown fault code | `KeyError` crash | shows as `"Fault NN"` | | EG4 discovery configs | missing (purged) | 207 retained, InfluxDB unblocked | ## Files touched ``` M LVX6048/bin/lvx-resolve-links (always-exit-0; relink-on-change; auto-restart powermon if symlinks move) M LVX6048/config/powermon/powermon.yaml (added FWS poll @ 30s) M LVX6048/config/powermon/powermon2.yaml (same) M LVX6048/etc/systemd/system/powermon.service (StartLimitIntervalSec=0) M LVX6048/etc/systemd/system/powermon.service.d/10-resolver.conf (Requires= -> Wants=) M LVX6048/etc/systemd/system/powermon2.service (same) M LVX6048/etc/systemd/system/powermon2.service.d/10-resolver.conf (same) M LVX6048/install.sh (installs the timer) M LVX6048/powermon-patches/pi18.py (defensive fault-code decoder, 00-99) A LVX6048/etc/systemd/system/lvx-resolve-links.timer (every 5 min) A LVX6048/2026-04-28.md (this file) ``` ## How to verify ```bash # Timer running? systemctl list-timers lvx-resolve-links.timer # Resolver idempotent? (no powermon bounce on no-change) sudo systemctl restart lvx-resolve-links.service journalctl -u lvx-resolve-links.service -n 8 --no-pager # Expect: "(unchanged)" lines, no "restarting powermon" line. # Wants= confirmed? systemctl show powermon.service -p Wants -p Requires # Expect: Wants=...lvx-resolve-links.service... ; Requires= line should NOT # include lvx-resolve-links. # Synthetic morning-blip test (optional, disruptive): sudo rm /dev/lvx6048-{1,2} sudo systemctl restart powermon.service # Expect: powermon enters Restart loop; within 5 min the timer fires the # resolver, recreates symlinks, powermon's next retry succeeds. # Fault polling alive mosquitto_sub -h -u mqtt -P -W 35 -v \ -t 'homeassistant/sensor/lvx6048_1_fault_code/state' \ -t 'homeassistant/sensor/lvx6048_2_fault_code/state' # Expect: "No fault" published every 30 s on each unit. ``` ## Loose ends / next pass - **FWS warning booleans aren't getting individual HA entities.** The 16 `enabled/disabled` flags (PV loss, over-temp, fan locked, …) are decoded by powermon's screen formatter but the hass formatter filters them because they lack `unit_of_measurement` / `device_class` / `reading_type` metadata. Worth a separate pass to expose them as `binary_sensor` entities so HA gets a real "PV loss" indicator alongside `fault_code`. - **LCD code format confirmation.** Next time you can look at the LCD, check whether warning codes display as bare "32", "W32", or something else — informs whether to add a friendly mapping for warning codes in the docs. - **Faster timer cadence?** Currently 5 min (worst-case ~2 min gap). Could drop to 1–2 min if morning blips become more frequent. Trade- off: more steady-state resolver runs (each costs one PI18 ID query per inverter, harmless but visible in logs). - **eg4-battery discovery-config retention.** The configs DID get purged at some point — not certain what triggered it. Next investigation: confirm whether `eg4-purge-orphans` is over-eager, whether the broker is dropping retains, or whether a daemon restart is needed. Worth a `mosquitto_sub` watch on the broker for retain changes.