diff --git a/LVX6048/lvx-flash/profiles/eg4-lp4-v2.yaml b/LVX6048/lvx-flash/profiles/eg4-lp4-v2.yaml index 1a48dd5..5296ceb 100644 --- a/LVX6048/lvx-flash/profiles/eg4-lp4-v2.yaml +++ b/LVX6048/lvx-flash/profiles/eg4-lp4-v2.yaml @@ -17,6 +17,9 @@ # stop_charge 54.0 V — grid charges only to ~mid-knee; solar handles the bulk top-off # stop_dis 48.0 V = 3.000 V/cell — soft "switch to grid" point # cutoff 48.0 V = 3.000 V/cell — inverter hard shutdown floor (BMS still protects below) +# (Floor reviewed 2026-06-24: deliberately kept at 48.0/3.00 V for cycle-life margin. +# Lowering to 46-47 V would unlock only a few % of usable LFP capacity and isn't +# worth the deeper cycling on this large, non-capacity-constrained bank.) # Conservative off-grid policy: keep grid as a soft top-up, let solar do the bulk work. # # Current rationale (600 Ah bank):