working in production - not entirely validated. parallel mode working.
This commit is contained in:
39
LVX6048/2026-04-26-lvx6048_2-dump
Normal file
39
LVX6048/2026-04-26-lvx6048_2-dump
Normal file
@@ -0,0 +1,39 @@
|
||||
# LVX6048 settings profile. Edit freely; all keys are optional.
|
||||
# `flash.py diff` previews changes; `flash.py apply --confirm` writes.
|
||||
|
||||
# enum: AGM | FLOODED | USER
|
||||
battery_type: AGM
|
||||
|
||||
# V 40.0..48.0 — hard shutdown; must be < stop_discharge_voltage. Only honored when battery_type=USER.
|
||||
cutoff_voltage: 40.8
|
||||
|
||||
# V 44.0..51.0 — switch battery→grid below this (pair: stop_charge_voltage). Only honored when battery_type=USER.
|
||||
stop_discharge_voltage: 46.0
|
||||
|
||||
# V 48.0..58.4 — CC→CV transition (pair: float_voltage; must be >= float_voltage). Only honored when battery_type=USER.
|
||||
bulk_voltage: 56.4
|
||||
|
||||
# A 2,10,20,30,40,50,60,70,80 — grid-side cap only
|
||||
max_utility_charging_current: 30
|
||||
|
||||
# A 10,20,30,40,50,60,70,80 — combined solar+AC cap
|
||||
max_charging_current: 60
|
||||
|
||||
# enum: solar_utility_battery | solar_battery_utility
|
||||
output_source_priority: solar_battery_utility
|
||||
|
||||
# enum: solar_first | solar_and_utility | solar_only
|
||||
charger_priority: solar_first
|
||||
|
||||
# enum: battery_load_utility_ac | load_battery_utility
|
||||
solar_power_priority: battery_load_utility_ac
|
||||
|
||||
# enum: enabled | disabled (PEI/PDI)
|
||||
grid_tie: disabled
|
||||
|
||||
# V 0 (=Full) or 48.0..58.0 — switch grid→battery above this (pair: stop_discharge_voltage). Only honored when battery_type=USER.
|
||||
stop_charge_voltage: 54.0
|
||||
|
||||
# V 48.0..58.4 — held while on grid (pair: bulk_voltage; must be <= bulk_voltage). Only honored when battery_type=USER.
|
||||
float_voltage: 54.0
|
||||
|
||||
Reference in New Issue
Block a user