C_BULK1 100u 25V->35V — must survive SMBJ18A clamp (<=29.2V at rated surge)
25V electrolytic sat directly on VIN_PROT where the TVS clamps up to 29.2V; 35V-rated part in the same 8x10 can. Regen diff = 1 line. ERC 133->133; analyzer diff unchanged. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
@@ -2002,7 +2002,7 @@
|
||||
(exclude_from_sim no) (in_bom yes) (on_board yes) (dnp no)
|
||||
(uuid "307c2b9f-38c6-58a7-8692-3a828d80213e")
|
||||
(property "Reference" "C_BULK1" (at 172.72 79.01 0) (effects (font (size 1.27 1.27)) (justify left)))
|
||||
(property "Value" "100u/25V" (at 172.72 81.01 0) (effects (font (size 1.27 1.27)) (justify left)))
|
||||
(property "Value" "100u/35V" (at 172.72 81.01 0) (effects (font (size 1.27 1.27)) (justify left)))
|
||||
(property "Footprint" "Capacitor_SMD:CP_Elec_8x10" (at 170.18 80.01 0) (effects (font (size 1.27 1.27)) (hide yes)))
|
||||
(property "Datasheet" "" (at 170.18 80.01 0) (effects (font (size 1.27 1.27)) (hide yes)))
|
||||
(property "Description" "" (at 170.18 80.01 0) (effects (font (size 1.27 1.27)) (hide yes)))
|
||||
|
||||
Reference in New Issue