Documentation: Arming Class

1. Purpose

The Arming class orchestrates the complete arming sequence for Data Acquisition System (DAS) devices. It manages configuration application, flash memory clearing, pre-arm validation (including level trigger checks), and the final arm execution. This class serves as the primary controller for transitioning DAS hardware from an idle state to an armed, trigger-ready state in test measurement scenarios.


2. Public Interface

Arming()

Signature: public Arming()

Default constructor. Initializes a new instance with a Configuration object.


SetConfigAndFlashClear

Signature:

public bool SetConfigAndStartFlashClear(
    DataModel.TestTemplate currentTest,
    List<IDASCommunication> dasList,
    Dictionary<string, int> dasSampleRateList,
    double duration,
    StatusHelpers.SetProgressValueDelegate setProgressFunction,
    ServiceBase.ServiceCallbackErrorEventHandler onError)

Behavior: Entry point for the arming workflow. Configures DAS modules with test parameters (post-trigger duration, pre-trigger seconds, number of events, wake-up motion timeout), applies configuration via Configuration.SetConfig(), and initiates the flash clear sequence. Returns true on success, false on failure.


SoftwareTrigger

Signature:

public void SoftwareTrigger(List<IDASCommunication> dasList)

Behavior: Sends a software trigger command to all DAS devices in the list. Executes within the DASHardware.GetArmStatusLock. Logs failures via APILogger.Log().


DisarmAsync

Signature:

public void DisarmAsync(List<IDASCommunication> dasList)

Behavior: Public entry point for disarming DAS devices. Delegates to DisarmSync() internally (despite the async naming).


3. Invariants

  • Thread Safety: All hardware operations (FlashErase, PrepareArmFunc, ArmNowFunc, SoftwareTrigger, DisarmSync) execute within a lock on DASHardware.GetArmStatusLock.
  • Pre-trigger Calculation: Pre-trigger seconds is always calculated as TSRAIR.TSRAIR_MAX_PRE_TRIGGER_SAMPLES / sampleRate for each DAS.
  • Flash Clear Prerequisite: Flash memory must be successfully erased before proceeding to PrepareArmFunc.
  • Level Trigger Validation: If currentTest.LevelTriggerChannels.Count > 0, the system checks for already-level-triggered channels and fails if any are detected.
  • Failure Propagation: Any failure during the arming sequence results in false return and invocation of the onError callback.
  • Disarm on Partial Failure: If some devices arm successfully while others fail, all devices are disarmed for safety (per FogBugz 4527).

4. Dependencies

This Module Depends On:

Dependency Usage
DTS.Common.Interface.DASFactory.IDASCommunication DAS device abstraction
DTS.Common.Utilities.Logging.APILogger Logging
DTS.DASLib.Service.ArmingService Service layer for arming operations
DTS.DASLib.Service.ServiceBase Callback infrastructure
DTS.Common.SharedResource.Strings.StringResources Localized error messages
DTS.Common.DataModel.Common.StatusHelpers Progress reporting helpers
DTS.Common.DataModel.Common.DASHardware Hardware lock singleton
DTS.Common.Enums.TSRAIRGo.TSRAIRGoStatus Status type enums
DTS.Common.Constant.DASSpecific.TSRAIR Constants including TSRAIR_MAX_PRE_TRIGGER_SAMPLES
DTS.Common.DataModel.Classes.TSRAIRGo.Configuration Configuration application

Data Types Referenced:

  • DataModel.TestTemplate - Test configuration container
  • AnalogInputDASChannel - Channel type with AlreadyLevelTriggered property
  • ArmStatus - Arm state tracking object

5. Gotchas

Namespace Mismatch

The file path indicates DTS.Common.DataModel but the namespace is declared as DataPROWin7.DataModel.Classes. This may cause confusion or require external aliasing.

Misleading Async Naming

DisarmAsync() is not asynchronous—it calls DisarmSync() which blocks on a ManualResetEvent. The naming is misleading.

Magic Numbers

  • ARM_NOW_TIMEOUT = 30000 (30 seconds)
  • 600000 (10 minutes) passed to ReadyForArm()
  • 50 ms polling interval used throughout
  • Hardcoded 30000 and dasList.Count > 1 in PreparedArmNowFunc with a TODO comment: "///////////fix the 30000 and 1 (at least)"

Historical Bug Fixes Referenced

  • FB 26980: Override mod.NumberOfEvents to ensure correct value
  • 39345: Don't hang if Flash Erase fails
  • 4527: Disarm all devices if any fail during arm (safety measure)
  • 15630: Limit EnableFaultChecking to single unit at a time for TDAS with rack
  • 15267: Stop on ERR response from TDAS ARM RF

Unused Code Path

In ArmNowFunc(), there is an empty conditional block:

if (Common.SerializedSettings.StoreTestHistoryInDb)
{
    //add code here?
}

This suggests incomplete implementation.

Polling Pattern