ALTER PROCEDURE [dbo].[sp_DBImportSensorsDigitalOut]
|
|
@DigitalOutSensors xml
|
|
,@errorNumber int output
|
|
,@errorMessage nvarchar(250) output
|
|
AS
|
|
BEGIN
|
|
set @errorNumber = 0
|
|
set @errorMessage = ''
|
|
|
|
declare @tSensorsDigitalOut table (
|
|
[SerialNumber] [nvarchar](50),
|
|
[DelayMS] [float],
|
|
[DurationMS] [smallint],
|
|
[OutputMode] [smallint],
|
|
[LimitDuration] [bit],
|
|
[LastModified] [datetime],
|
|
[LastModifiedBy] [nvarchar](50),
|
|
[Version] [int],
|
|
[LocalOnly] [bit],
|
|
[DurationMSFloat] [float],
|
|
/*[UserTags] [varbinary](max),*/
|
|
[UserTagsText] [nvarchar](4000),
|
|
[Processed] [bit])
|
|
|
|
insert into @tSensorsDigitalOut
|
|
(SerialNumber
|
|
, DelayMS
|
|
, DurationMS
|
|
, OutputMode
|
|
, LimitDuration
|
|
, LastModified
|
|
, LastModifiedBy
|
|
, [Version]
|
|
, LocalOnly
|
|
, DurationMSFloat
|
|
/*, UserTags*/
|
|
, UserTagsText
|
|
,Processed)
|
|
select
|
|
t.x.value('SerialNumber[1]', 'nvarchar(50)') as SerialNumber
|
|
, t.x.value('DigitalOutputDelayMS[1]', 'float') as DelayMS
|
|
, t.x.value('DigitalOutputDurationMS[1]', 'smallint') as DurationMS
|
|
, dbo.foo_DigitalOutputOutputModeConverterToInt(t.x.value('DigitalOutputOutputMode[1]', 'nvarchar(50)')) as OutputMode
|
|
, t.x.value('DigitalOutputLimitDuration[1]', 'bit') as LimitDuration
|
|
|
|
, getdate() as LastModified /* t.x.value('@LastModified', 'datetime') */
|
|
, 'DBImport' as ModifiedBy /* t.x.value('@ModifiedBy', 'varchar(50)') */
|
|
, t.x.value('Version[1]', 'int') as Version
|
|
, t.x.value('LocalOnly[1]', 'bit') as LocalOnly
|
|
, t.x.value('DigitalOutputDurationMS[1]', 'float') as DurationMSFloat /* ???? */
|
|
/*, CASE WHEN t.x.value('UserTags[1]', 'varbinary(max)') IS NULL THEN 0
|
|
ELSE t.x.value('UserTags[1]', 'varbinary(max)') end as UserTags */
|
|
, CASE WHEN t.x.value('UserTags[1]', 'nvarchar(4000)') IS NULL THEN ''
|
|
ELSE t.x.value('UserTags[1]', 'nvarchar(4000)') end as UserTagsText
|
|
, 0
|
|
from @DigitalOutSensors.nodes('/Sensors/SensorData') t(x) OPTION (OPTIMIZE FOR ( @DigitalOutSensors = NULL ))
|
|
|
|
while (Select Count(*) From @tSensorsDigitalOut Where Processed = 0) > 0
|
|
Begin
|
|
begin try
|
|
begin transaction tSensorsDigitalOut
|
|
|
|
|
|
declare @SerialNumber nvarchar(50) = null
|
|
,@DelayMS float
|
|
,@DurationMS smallint
|
|
,@DurationMSFloat float
|
|
,@OutputMode smallint
|
|
,@LimitDuration bit
|
|
,@LastModified datetime
|
|
,@LastModifiedBy nvarchar(50)
|
|
,@Version int
|
|
,@UserTags varbinary(max)
|
|
,@UserTagsText nvarchar(4000)
|
|
,@new_id int
|
|
|
|
select top 1 @SerialNumber = SerialNumber
|
|
,@DelayMS = DelayMS
|
|
,@DurationMS = DurationMS
|
|
,@DurationMSFloat = DurationMSFloat
|
|
,@OutputMode = OutputMode
|
|
,@LimitDuration = LimitDuration
|
|
,@LastModified = LastModified
|
|
,@LastModifiedBy = LastModifiedBy
|
|
,@Version = [Version]
|
|
/*,@UserTags = UserTags*/
|
|
,@UserTagsText = UserTagsText
|
|
from @tSensorsDigitalOut where Processed = 0
|
|
|
|
declare @tagTable TABLE (Element nvarchar(4000), Processed bit)
|
|
declare @tagIdTable TABLE (Id int, Processed bit)
|
|
insert into @tagTable (Element, Processed) select * from dbo.foo_SplitDelimitedString(@UserTagsText, ',')
|
|
|
|
/*call foo_IdGetTag to get the tag id */
|
|
while (Select Count(*) From @tagTable Where Processed = 0) > 0
|
|
Begin
|
|
begin try
|
|
declare @tagName nvarchar(4000)
|
|
declare @tagIdTemp int
|
|
select top 1 @tagName = Element from @tagTable where Processed = 0
|
|
set @tagIdTemp = dbo.foo_IdGetTag(@tagName)
|
|
insert into @tagIdTable (Id, Processed) VALUES (@tagIdTemp, 0)
|
|
end try
|
|
begin catch
|
|
set @errorNumber = error_number()
|
|
set @errorMessage = error_message()
|
|
rollback transaction tSensorsAnalog
|
|
end catch;
|
|
update @tagTable set Processed = 1 where Element = @tagName
|
|
End
|
|
|
|
/*store in a byte array*/
|
|
while (Select Count(*) From @tagIdTable Where Processed = 0) > 0
|
|
Begin
|
|
begin try
|
|
declare @tagId int
|
|
declare @tagIdByte varbinary(4)
|
|
select top 1 @tagId = Id from @tagIdTable where Processed = 0
|
|
--set @tagIdByte = dbo.foo_ConvertIntToBytes(@tagId)
|
|
set @tagIdByte = CONVERT(VARBINARY(MAX), REVERSE(CONVERT(VARBINARY(4), @tagId)))
|
|
set @UserTags = CONVERT(varbinary(max), CONCAT(@UserTags, @tagIdByte))
|
|
end try
|
|
begin catch
|
|
set @errorNumber = error_number()
|
|
set @errorMessage = error_message()
|
|
rollback transaction tSensorsAnalog
|
|
end catch;
|
|
update @tagIdTable set Processed = 1 where Id = @tagId
|
|
End
|
|
|
|
exec dbo.sp_SensorsDigitalOutUpdateInsert @SerialNumber
|
|
,@DelayMS
|
|
,@DurationMS
|
|
,@DurationMSFloat
|
|
,@OutputMode
|
|
,@LimitDuration
|
|
,@LastModified
|
|
,@LastModifiedBy
|
|
,@Version
|
|
,@UserTags
|
|
,@new_id output
|
|
,@errorNumber output
|
|
,@errorMessage output
|
|
|
|
update @tSensorsDigitalOut set Processed = 1 where SerialNumber = @SerialNumber
|
|
|
|
commit transaction tSensorsDigitalOut
|
|
|
|
end try
|
|
begin catch
|
|
set @errorNumber = error_number()
|
|
set @errorMessage = error_message()
|
|
rollback transaction tSensorsDigitalOut
|
|
end catch;
|
|
end
|
|
END
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|