namespace DTS.Common.Interface.DASFactory.ARM
|
|
{
|
|
public interface IArmStatusData
|
|
{
|
|
/// <summary>
|
|
/// returns true if unit received InvalidMode to query commands during initial setup
|
|
/// 15932 Error when performing test when S6A is streaming
|
|
/// this is used in some places currently to detect when a unit is streaming
|
|
/// </summary>
|
|
bool ReceivedInvalidModeDuringSetup { get; set; }
|
|
/// <summary>
|
|
/// clears any flags set or needed for triggercheck
|
|
/// </summary>
|
|
void ClearTriggerCheckStatus();
|
|
|
|
/// <summary>
|
|
/// Is the DAS currently armed?
|
|
/// </summary>
|
|
bool IsArmed { get; set; }
|
|
|
|
/// <summary>
|
|
/// Has the DAS sensed a trigger?
|
|
/// </summary>
|
|
bool IsTriggered { get; set; }
|
|
|
|
/// <summary>
|
|
/// a little bit distinct from IsTriggered
|
|
/// in that IsTriggerShorted is only set during TriggerCheck
|
|
/// while IsTriggered is set in many places
|
|
/// </summary>
|
|
bool IsTriggerShorted { get; set; }
|
|
|
|
/// <summary>
|
|
/// indicates that trigger was shorted
|
|
/// is only set during triggercheck
|
|
/// </summary>
|
|
bool IsStartShorted { get; set; }
|
|
|
|
/// <summary>
|
|
/// Is the DAS currently recording sample data?
|
|
/// </summary>
|
|
bool IsRecording { get; set; }
|
|
|
|
/// <summary>
|
|
/// Has the DAS faulted?
|
|
/// </summary>
|
|
bool IsFaulted { get; set; }
|
|
|
|
/// <summary>
|
|
/// Is the DAS in real time mode?
|
|
/// </summary>
|
|
bool IsInRealtime { get; set; }
|
|
|
|
/// <summary>
|
|
/// is the DAS in flash write (G5)
|
|
/// </summary>
|
|
bool IsInFlashWrite { get; set; }
|
|
|
|
/// <summary>
|
|
/// used for the times when TDAS ARM STAT READ just doesn't return anything
|
|
/// </summary>
|
|
bool IsUndefined { get; set; }
|
|
|
|
/// <summary>
|
|
/// Is the DAS in post test diagnostics
|
|
/// </summary>
|
|
bool IsInPostTestDiagnostics { get; set; }
|
|
|
|
/// <summary>
|
|
/// How many seconds are left of recording?
|
|
/// </summary>
|
|
double TimeRemainingSeconds { get; set; }
|
|
|
|
/// <summary>
|
|
/// what percentage is complete [flashwrite]
|
|
/// </summary>
|
|
double PercentComplete { get; set; }
|
|
|
|
/// <summary>
|
|
/// How many samples total will the DAS be recording this test?
|
|
/// </summary>
|
|
ulong TotalSamples { get; set; }
|
|
|
|
/// <summary>
|
|
/// What sample are we currently recording?
|
|
/// </summary>
|
|
ulong CurrentSample { get; set; }
|
|
|
|
/// <summary>
|
|
/// At what sample rate are we currently recording?
|
|
/// </summary>
|
|
uint SampleRate { get; set; }
|
|
|
|
/// <summary>
|
|
/// What's the current input voltage?
|
|
/// </summary>
|
|
double? InputMilliVolts { get; set; }
|
|
|
|
/// <summary>
|
|
/// What's the current battery voltage (null if no battery)?
|
|
/// </summary>
|
|
double? BatteryMilliVolts { get; set; }
|
|
|
|
/// <summary>
|
|
/// Which event number is currently being recorded?
|
|
/// </summary>
|
|
int? EventNumber { get; set; }
|
|
//FB 26817
|
|
/// <summary>
|
|
/// The Max number of events supported by a device
|
|
/// </summary>
|
|
ushort? MaxEventsPossible { get; set; }
|
|
int RecordingMode { get; set; }
|
|
/// <summary>
|
|
/// optional fault message if there is a fault
|
|
/// (software will flag some faults and when we do we know what caused it)
|
|
/// </summary>
|
|
string FaultMessage { get; set; }
|
|
|
|
bool IsRearming { get; set; }
|
|
|
|
bool HasBeenRecording { get; set; }
|
|
|
|
double? TimeLeftInArm { get; set; }
|
|
}
|
|
}
|