Files
2026-04-17 14:55:32 -04:00

3.7 KiB

source_files, generated_at, model, schema_version, sha256
source_files generated_at model schema_version sha256
DataPRO/Modules/DatabaseImporter/DatabaseImport/DASConcepts/Test.Module.Channel.Sensor.SensorUnits.cs
DataPRO/Modules/DatabaseImporter/DatabaseImport/DASConcepts/Test.Module.Channel.Sensor.Bridge.cs
DataPRO/Modules/DatabaseImporter/DatabaseImport/DASConcepts/DigitalInputScaleMultiplier.cs
DataPRO/Modules/DatabaseImporter/DatabaseImport/DASConcepts/LinearizationFormula.cs
2026-04-17T15:53:56.452748+00:00 zai-org/GLM-5-FP8 1 d057a2503f607f02

Documentation: DatabaseImport DAS Concepts

1. Purpose

This module defines sensor-related data structures and parsing logic for a Data Acquisition System (DAS) database import facility. It provides enumeration types for sensor sensitivity units and bridge configurations, a class for transforming digital input values to arbitrary scales, and a comprehensive linearization formula system supporting multiple calibration formats (IRTracc variants and polynomial). These components are part of a larger Test class hierarchy representing channel and sensor configuration concepts.


2. Public Interface

Test.Module.Channel.Sensor.SensUnits (enum)

Location: Test.Module.Channel.Sensor.SensorUnits.cs

Enumeration of sensitivity unit types for sensors.

Member Value Description Attribute
NONE 0 "NONE" - For polynomial sensors
mV 1 "mV" - Millivolts at capacity EU
mVperV 2 "mV/V" - Excitation proportional at capacity EU
mVperVperEU 3 "mV/V/EU" - Excitation proportional per EU
mVperEU 4 "mV/EU" - Millivolts per engineering unit

Test.Module.Channel.Sensor.BridgeType (enum)

Location: Test.Module.Channel.Sensor.Bridge.cs

Enumeration of bridge/sensor configuration types. Values are bit flags.

Member Value Description Attribute
IEPE 1 (1 << 0) "IEPE"
QuarterBridge 2 (1 << 1) "Quarter"
HalfBridge 4 (1 << 2) "Bridge-Half"
FullBridge 8 (1 << 3) "Bridge-Full"
DigitalInput 16 (1 << 4) "DigitalInput"
SQUIB 32 (1 << 5) "SQUIB"
TOMDigital 64 (1 << 6) "TOMDigital"
HalfBridge_SigPlus 128 (1 << 7) "Bridge-Half SigPlus"

DigitalInputScaleMultiplier (class)

Location: DigitalInputScaleMultiplier.cs

Transforms digital input data by mapping binary 0/1 values to arbitrary low/high display values.

Nested Enum:

public enum Forms { ArbitraryLowAndHigh }

Properties:

  • Forms Form { get; set; } — Default: Forms.ArbitraryLowAndHigh
  • double DefaultValue { get; set; } — Value to display for digital 0 (OFF)
  • double ActiveValue { get; set; } — Value to display for digital 1 (ON), default: 1.0

Constructors:

public DigitalInputScaleMultiplier()  // Sets DefaultValue to 0.0
public DigitalInputScaleMultiplier(DigitalInputScaleMultiplier copy)  // Copy constructor

Methods:

public void FromDbSerializeString(string s)

Deserializes from a string format. Silently returns on null input. Throws NotSupportedException for invalid formats.


LinearizationFormula (class)

Location: LinearizationFormula.cs

Holds linearization parameters for sensor calibration, supporting multiple formula styles.

Properties:

  • NonLinearStyles NonLinearStyle { get; set; } — Default: NonLinearStyles.IRTraccDiagnosticsZero
  • double PolynomialSensitivity { get; set; } — Default: 1.0
  • double LinearizationExponent { get; set; } — Default: 1.0
  • double MMPerV { get; set; } — Millimeters per volt (see Gotchas)
  • double MVAt0MM { get; set; } — Millivol