IF EXISTS (SELECT * FROM sys.objects WHERE object_id = OBJECT_ID(N'[dbo].[sp_DBImportSensorsSquib]') AND type in (N'P', N'PC'))
|
|
DROP PROCEDURE [dbo].[sp_DBImportSensorsSquib]
|
|
GO
|
|
SET ANSI_NULLS ON
|
|
GO
|
|
SET QUOTED_IDENTIFIER ON
|
|
GO
|
|
IF NOT EXISTS (SELECT * FROM sys.objects WHERE object_id = OBJECT_ID(N'[dbo].[sp_DBImportSensorsSquib]') AND type in (N'P', N'PC'))
|
|
BEGIN
|
|
EXEC dbo.sp_executesql @statement = N'CREATE PROCEDURE [dbo].[sp_DBImportSensorsSquib] AS'
|
|
END
|
|
GO
|
|
ALTER PROCEDURE [dbo].[sp_DBImportSensorsSquib]
|
|
@SquibSensors xml
|
|
,@errorNumber int output
|
|
,@errorMessage nvarchar(250) output
|
|
AS
|
|
BEGIN
|
|
set @errorNumber = 0
|
|
set @errorMessage = ''
|
|
|
|
declare @tSensorsSquib table
|
|
([SerialNumber] [nvarchar](50),
|
|
[BypassCurrentFilter] [bit],
|
|
[BypassVoltageFilter] [bit],
|
|
[DelayMS] [float],
|
|
[DurationMS] [float],
|
|
[FireMode] [smallint],
|
|
[ISOCode] [nvarchar](50),
|
|
[MeasurementType] [smallint],
|
|
[SquibOutputCurrent] [float],
|
|
[SquibToleranceLow] [float],
|
|
[SquibToleranceHigh] [float],
|
|
[LimitDuration] [bit],
|
|
[ArticleId] [nvarchar](50),
|
|
[LocalOnly] [bit],
|
|
[Version] [int],
|
|
[LastModified] [datetime],
|
|
[LastModifiedBy] [nvarchar](50),
|
|
[UserValue1] [nvarchar](255),
|
|
[UserValue2] [nvarchar](255),
|
|
[UserValue3] [nvarchar](255),
|
|
[UserTags] [varbinary](max),
|
|
[Processed] [bit])
|
|
|
|
insert into @tSensorsSquib
|
|
(SerialNumber
|
|
, BypassCurrentFilter
|
|
, BypassVoltageFilter
|
|
, DelayMS
|
|
, DurationMS
|
|
, FireMode
|
|
, ISOCode
|
|
, MeasurementType
|
|
, SquibOutputCurrent
|
|
, SquibToleranceLow
|
|
, SquibToleranceHigh
|
|
, LimitDuration
|
|
, ArticleId
|
|
, LocalOnly
|
|
, [Version]
|
|
, LastModified
|
|
, LastModifiedBy
|
|
, UserValue1
|
|
, UserValue2
|
|
, UserValue3
|
|
, UserTags
|
|
,Processed)
|
|
select
|
|
t.x.value('@SquibDescription', 'varchar(50)') as SerialNumber
|
|
, t.x.value('@BypassFilter', 'bit') as BypassCurrentFilter
|
|
, t.x.value('@BypassVoltageFilter', 'bit') as BypassVoltageFilter
|
|
, t.x.value('@DelayMS', 'float') as DelayMS
|
|
, t.x.value('@DurationMS', 'float') as DurationMS
|
|
, t.x.value('@FireMode', 'varchar(50)') as FireMode
|
|
, t.x.value('@ISOCode', 'varchar(50)') as ISOCode
|
|
, t.x.value('@MeasurementType', 'varchar(50)') as MeasurementType
|
|
, t.x.value('@SquibOutputCurrent', 'float') as SquibOutputCurrent
|
|
, t.x.value('@SquibToleranceLow', 'float') as SquibToleranceLow
|
|
, t.x.value('@SquibToleranceHigh', 'float') as SquibToleranceHigh
|
|
, t.x.value('@LimitDuration', 'bit') as LimitDuration
|
|
, t.x.value('@ArticleId', 'varchar(max)') as SquibArticleId
|
|
, t.x.value('@LocalOnly', 'bit') as LocalOnly
|
|
, t.x.value('@Version', 'int') as Version
|
|
, getdate() as LastModified /* t.x.value('@LastModified', 'datetime') */
|
|
, 'DBImport' as ModifiedBy /* t.x.value('@ModifiedBy', 'varchar(50)') */
|
|
|
|
, t.x.value('@UserValue1', 'varchar(50)') as UserValue1
|
|
, t.x.value('@UserValue2', 'varchar(50)') as UserValue2
|
|
, t.x.value('@UserValue3', 'varchar(50)') as UserValue3
|
|
, t.x.value('@UserTags', 'varbinary(max)') as UserTags
|
|
, 0
|
|
from @SquibSensors.nodes('/Sensors/SensorData') t(x) OPTION (OPTIMIZE FOR ( @SquibSensors = NULL ))
|
|
|
|
while (Select Count(*) From @tSensorsSquib Where Processed = 0) > 0
|
|
Begin
|
|
begin try
|
|
begin transaction tSensorsSquib
|
|
|
|
declare @SerialNumber nvarchar(50)
|
|
,@BypassCurrentFilter bit
|
|
,@BypassVoltageFilter bit
|
|
,@DelayMS float
|
|
,@DurationMS float
|
|
,@FireMode smallint
|
|
,@ISOCode nvarchar(50)
|
|
,@MeasurementType smallint
|
|
,@SquibOutputCurrent float
|
|
,@SquibToleranceLow float
|
|
,@SquibToleranceHigh float
|
|
,@LimitDuration bit
|
|
,@ArticleId nvarchar(50)
|
|
,@LocalOnly bit
|
|
,@Version int
|
|
,@LastModified datetime
|
|
,@LastModifiedBy nvarchar(50)
|
|
,@UserValue1 nvarchar(255)
|
|
,@UserValue2 nvarchar(255)
|
|
,@UserValue3 nvarchar(255)
|
|
,@UserTags varbinary(max)
|
|
,@new_id int
|
|
|
|
select top 1
|
|
@SerialNumber = SerialNumber
|
|
,@BypassCurrentFilter = BypassCurrentFilter
|
|
,@BypassVoltageFilter = BypassVoltageFilter
|
|
,@DelayMS = DelayMS
|
|
,@DurationMS = DurationMS
|
|
,@FireMode = FireMode
|
|
,@ISOCode = ISOCode
|
|
,@MeasurementType = MeasurementType
|
|
,@SquibOutputCurrent = SquibOutputCurrent
|
|
,@SquibToleranceLow = SquibToleranceLow
|
|
,@SquibToleranceHigh = SquibToleranceHigh
|
|
,@LimitDuration = LimitDuration
|
|
,@ArticleId = ArticleId
|
|
,@LocalOnly = LocalOnly
|
|
,@Version = Version
|
|
,@LastModified = LastModified
|
|
,@LastModifiedBy = LastModifiedBy
|
|
,@UserValue1 = UserValue1
|
|
,@UserValue2 = UserValue2
|
|
,@UserValue3 = UserValue3
|
|
,@UserTags = UserTags
|
|
from @tSensorsSquib where Processed = 0
|
|
|
|
exec dbo.sp_SensorsSquibUpdateInsert @SerialNumber
|
|
,@BypassCurrentFilter
|
|
,@BypassVoltageFilter
|
|
,@DelayMS
|
|
,@DurationMS
|
|
,@FireMode
|
|
,@ISOCode
|
|
,@MeasurementType
|
|
,@SquibOutputCurrent
|
|
,@SquibToleranceLow
|
|
,@SquibToleranceHigh
|
|
,@LimitDuration
|
|
,@ArticleId
|
|
,@LocalOnly
|
|
,@Version
|
|
,@LastModified
|
|
,@LastModifiedBy
|
|
,@UserValue1
|
|
,@UserValue2
|
|
,@UserValue3
|
|
,@UserTags
|
|
,@new_id output
|
|
,@errorNumber output
|
|
,@errorMessage output
|
|
|
|
update @tSensorsSquib set Processed = 1 where SerialNumber = @SerialNumber
|
|
commit transaction tSensorsSquib
|
|
end try
|
|
begin catch
|
|
set @errorNumber = error_number()
|
|
set @errorMessage = error_message()
|
|
rollback transaction tSensorsSquib
|
|
end catch;
|
|
end
|
|
END
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GO
|