Files
DP44/DataPRO/Modules/Database/DatabaseMigrationScripts/.svn/pristine/50/50fe3cd382de98e26012cf103082a8eaf0d4d7ed.svn-base
2026-04-17 14:55:32 -04:00

29 lines
2.7 KiB
Plaintext

CREATE PROCEDURE [dbo].[sp_SensorTestHistoryGet]
@SensorTestHistoryId BIGINT = NULL,
@TestHistoryId BIGINT = NULL,
@SensorId INT = NULL,
@SerialNumber NVARCHAR(MAX) = NULL
AS
BEGIN
SET NOCOUNT ON;
IF @SensorId IS NOT NULL
BEGIN
SELECT A.TestHistoryId, A.TestSetupId, A.TestSetupName, A.TestSetupDescription, A.TestId, A.Destructive, A.ArmTime, A.TestSetup, B.SensorTestHistoryId, B.SensorId, B.SerialNumber, B.Capacity, B.Range, B.CalibrationDate, B.HardwareChannelName, B.ISOChannelName, B.ISOCode, B.UserChannelName, B.UserCode, B.Sensitivity, B.FilterClass, B.IsProportional, B.LinearizationFormula, b.EID, B.MeasuredExcitation, B.MeasurementUnit, B.SamplesPerSecond, B.AAF
FROM [dbo].[TestHistory] AS A INNER JOIN [dbo].[SensorTestHistory] AS B ON A.TestHistoryId=B.TestHistoryId WHERE B.SensorId=@SensorId
END
ELSE IF @SensorTestHistoryId IS NOT NULL
BEGIN
SELECT A.TestHistoryId, A.TestSetupId, A.TestSetupName, A.TestSetupDescription, A.TestId, A.Destructive, A.ArmTime, A.TestSetup, B.SensorTestHistoryId, B.SensorId, B.SerialNumber, B.Capacity, B.Range, B.CalibrationDate, B.HardwareChannelName, B.ISOChannelName, B.ISOCode, B.UserChannelName, B.UserCode, B.Sensitivity, B.FilterClass, B.IsProportional, B.LinearizationFormula, b.EID, B.MeasuredExcitation, B.MeasurementUnit, B.SamplesPerSecond, B.AAF
FROM [dbo].[TestHistory] AS A INNER JOIN [dbo].[SensorTestHistory] AS B ON A.TestHistoryId=B.TestHistoryId WHERE B.SensorTestHistoryId=@SensorTestHistoryId
END
ELSE IF @TestHistoryId IS NOT NULL
BEGIN
SELECT A.TestHistoryId, A.TestSetupId, A.TestSetupName, A.TestSetupDescription, A.TestId, A.Destructive, A.ArmTime, A.TestSetup, B.SensorTestHistoryId, B.SensorId, B.SerialNumber, B.Capacity, B.Range, B.CalibrationDate, B.HardwareChannelName, B.ISOChannelName, B.ISOCode, B.UserChannelName, B.UserCode, B.Sensitivity, B.FilterClass, B.IsProportional, B.LinearizationFormula, b.EID, B.MeasuredExcitation, B.MeasurementUnit, B.SamplesPerSecond, B.AAF
FROM [dbo].[TestHistory] AS A INNER JOIN [dbo].[SensorTestHistory] AS B ON A.TestHistoryId=B.TestHistoryId WHERE B.TestHistoryId=@TestHistoryId
END
ELSE
BEGIN
SELECT A.TestHistoryId, A.TestSetupId, A.TestSetupName, A.TestSetupDescription, A.TestId, A.Destructive, A.ArmTime, A.TestSetup, B.SensorTestHistoryId, B.SensorId, B.SerialNumber, B.Capacity, B.Range, B.CalibrationDate, B.HardwareChannelName, B.ISOChannelName, B.ISOCode, B.UserChannelName, B.UserCode, B.Sensitivity, B.FilterClass, B.IsProportional, B.LinearizationFormula, b.EID, B.MeasuredExcitation, B.MeasurementUnit, B.SamplesPerSecond, B.AAF
FROM [dbo].[TestHistory] AS A INNER JOIN [dbo].[SensorTestHistory] AS B ON A.TestHistoryId=B.TestHistoryId WHERE B.SerialNumber=@SerialNumber
END
END