IF EXISTS (SELECT * FROM sys.objects WHERE object_id = OBJECT_ID(N'[dbo].[sp_LevelTriggersUpdate]') AND type in (N'P', N'PC')) DROP PROCEDURE [dbo].[sp_LevelTriggersUpdate] GO SET ANSI_NULLS ON GO SET QUOTED_IDENTIFIER ON GO IF NOT EXISTS (SELECT * FROM sys.objects WHERE object_id = OBJECT_ID(N'[dbo].[sp_LevelTriggersUpdate]') AND type in (N'P', N'PC')) BEGIN EXEC dbo.sp_executesql @statement = N'CREATE PROCEDURE [dbo].[sp_LevelTriggersUpdate] AS' END GO ALTER PROCEDURE [dbo].[sp_LevelTriggersUpdate] @TestSetupName nvarchar(255) ,@GroupSerialNumber nvarchar(255) ,@TestObjectChannelId nvarchar(255) ,@HardwareChannelId nvarchar(255) ,@SensorSerialNumber nvarchar(255) ,@GreaterThanEnabled bit ,@GreaterThanEU float ,@LessThanEnabled bit ,@LessThanEU float ,@InsideUpperEU float ,@InsideLowerEU float ,@OutsideUpperEU float ,@OutsideLowerEU float ,@TriggerInside bit ,@TriggerOutside bit ,@errorNumber int output ,@errorMessage nvarchar(250) output AS BEGIN SET NOCOUNT ON; set @errorNumber = 0 set @errorMessage = space(0) declare @TestSetupId int declare @TestObjectId int declare @DASId int declare @SensorId int declare @ChannelId int declare @MMEChannel bit declare @MMEChannelId int select @TestSetupId = TestSetupId from TestSetups where TestSetupName =@TestSetupName select @DASId = d.DASId from [dbo].[DAS] d where SerialNumber = left(@HardwareChannelId, charindex('_', @HardwareChannelId)-1) select @SensorId = SensorId from dbo.v_SensorSerialNumber where SerialNumber = @SensorSerialNumber select @TestObjectId = ts.TestObjectId from [dbo].[TestObjects] ts where ts.TestObjectName = @GroupSerialNumber set @ChannelId = right(@HardwareChannelId, LEN(@HardwareChannelId) - charindex('x', @HardwareChannelId)) set @MMEChannel = left(replace(@TestObjectChannelId, @GroupSerialNumber + '_', space(0)), 1) set @MMEChannelId = substring(@TestObjectChannelId, LEN(@TestObjectChannelId) - charindex('_', reverse(@TestObjectChannelId)) +2, charindex('_', reverse(@TestObjectChannelId))+1) UPDATE [dbo].[LevelTriggers] SET [DASId] = @DASId ,[MMEChannel] = @MMEChannel ,[MMEChannelId] = @MMEChannelId ,[HardwareChannelId] = @ChannelId ,[SensorId] = @SensorId ,[GreaterThanEnabled] = @GreaterThanEnabled ,[GreaterThanEU] = @GreaterThanEU ,[LessThanEnabled] = @LessThanEnabled ,[LessThanEU] = @LessThanEU ,[InsideUpperEU] = @InsideUpperEU ,[InsideLowerEU] = @InsideLowerEU ,[OutsideUpperEU] = @OutsideUpperEU ,[OutsideLowerEU] = @OutsideLowerEU ,[TriggerInside] = @TriggerInside ,[TriggerOutside] = @TriggerOutside WHERE [TestSetupId] = @TestSetupId and [TestObjectId] = @TestObjectId END GO