init
This commit is contained in:
38
Common/DTS.Common/Constant/DigitalInputs.cs
Normal file
38
Common/DTS.Common/Constant/DigitalInputs.cs
Normal file
@@ -0,0 +1,38 @@
|
||||
namespace DTS.Common.Constant
|
||||
{
|
||||
public static class DigitalInputs
|
||||
{
|
||||
/// <summary>
|
||||
/// magic number from CPB
|
||||
/// a transition across 19005 flips the bit
|
||||
/// UPDATE:
|
||||
/// Currently the plan for the DIM thresholds is:
|
||||
///1. Voltage input: 19661 (1.5V with sig- grounded)
|
||||
///2. Contact Closure: 19005 (stays the same as what it used to be)
|
||||
///VoltageInput should be used for digital modes THL and TLH
|
||||
/// </summary>
|
||||
public const double ConstantCurrentBreakPointDefault = 19005D;
|
||||
public const double VoltageInputBreakPointDefault = 19661D;
|
||||
/// <summary>
|
||||
/// the default value for whether to display SLICE PRO Digital ADC or not
|
||||
/// </summary>
|
||||
public const bool DisplaySPDADCDefault = false;
|
||||
/// <summary>
|
||||
/// the current constant current break point
|
||||
/// does not query value from storage, only holds value static and relies on value being set separately
|
||||
/// </summary>
|
||||
public static double ConstantCurrentBreakPoint { get; set; } = ConstantCurrentBreakPointDefault;
|
||||
/// <summary>
|
||||
/// the voltage input break point
|
||||
/// does not query value from storage, only holds value static and relies on value being set separately
|
||||
/// </summary>
|
||||
public static double VoltageInputBreakPoint { get; set; } = VoltageInputBreakPointDefault;
|
||||
|
||||
/// <summary>
|
||||
/// controls whether to display SLICE Pro Digital analog ADC
|
||||
/// does not query value from storage, only holds value static and relies on value being set separately
|
||||
/// </summary>
|
||||
public static bool DisplaySPDADC { get; set; } = DisplaySPDADCDefault;
|
||||
|
||||
}
|
||||
}
|
||||
Reference in New Issue