# Documentation: DASFactory Diagnostic & Configuration Classes
## 1. Purpose
This module provides core data structures for representing and managing diagnostic results and configuration data within the DASFactory subsystem. It defines classes to encapsulate CAN bus diagnostics (`CanDiagnostics`), test channel diagnostics (`TCDiagnosticResult`), raw diagnostic message rows (`DiagnosticMessageRow`), and hardware-specific configuration objects for temperature logging (`TemperatureConfig`) and TMNS (Telemetry Network Subsystem) streaming (`TMNSConfig`). These classes serve as standardized data contracts between diagnostic test execution, result reporting, and configuration management layers—primarily supporting CAN BIST (Built-In Self-Test) and environmental monitoring, with extensibility for future hardware types.
## 2. Public Interface
### `DiagnosticMessageRow`
- **`DiagnosticMessageRow(string field, string value, string verdict)`**
Constructor initializing all three properties. Used to hold a single diagnostic message row (e.g., from CAN BIST output).
- **`Field` (string, get/set)**
Name of the diagnostic field (e.g., "ErrorCounter", "StatusRegister").
- **`Value` (string, get/set)**
String representation of the diagnostic value.
- **`Verdict` (string, get/set)**
Pass/fail/other verdict for the field.
- **`ToString()` (override)**
Returns formatted string: `"Field: {Field}, Value: {Value}, Verdict: {Verdict}"`.
### `TCDiagnosticResult`
- **`ChannelName` (string, get/set)**
Human-readable name of the test channel.
- **`ChannelIndex` (int, get/set)**
Numeric index of the test channel.
- **`CurrentReading` (double?, get/set)**
Optional measured value (e.g., current in mA); `null` if not measured or unavailable.
- **`Status` (DiagnosticStatus, get/set)**
Overall diagnostic status (e.g., `Untested`, `Pass`, `Fail`).
- **`ConnectionStatus` (ConnectionStatuses, get/set)**
Connection state (e.g., `NotTested`, `Connected`, `Open`, `Short`).
- **`Copy(ITCDiagnosticResult source)`**
Copies all properties from `source` to this instance.
### `CanDiagnostics`
- **`Active` (bool, get/set)**
Whether this CAN channel is active.
- **`ChannelIndex` (int, get/set)**
CAN channel index (e.g., 0, 1).
- **`Data` (int, get/set)**
Raw data value from CAN diagnostics.
- **`ErrorFrame` (int, get/set)**
Count of error frames detected.
- **`Load` (double, get/set)**
Bus load percentage (0.0100.0).
- **`Overruns` (int, get/set)**
Count of overrun errors.
- **`LastUpdate` (DateTime, get/set)**
Timestamp of last diagnostic update.
- **`Errors` (int, read-only)**
Computed error count: `Overruns` if `ErrorFrame == 0`, otherwise `1 + Overruns`.
- **`ChannelName` (string, get/set)**
Human-readable CAN channel name.
- **`Copy(ICanDiagnosticResult source)`**
Copies all properties from `source` to this instance.
### `TemperatureConfig`
- **`LogEnable` (ushort, get/set)**
Enable flag for logging (typically 0 or 1).
- **`LogIntervalSec` (ushort, get/set)**
Logging interval in seconds.
- **`Channels` (ushort, get/set)**
Bitfield representing enabled temperature/humidity channels (maps to `_channels` BitArray).
- **`MCUTemp` (bool, get/set)**
Enables/disables MCU temperature logging.
- **`OnBoardHumidity` (bool, get/set)**
Enables/disables on-board humidity logging.
- **`EnvironmentalCh1``EnvironmentalCh4` (bool, get/set)**
Enables/disables individual environmental channels (Ch1Ch4).
- **`ToUShortArray()` (ushort[])**
Returns `[LogEnable, LogIntervalSec, Channels, Reserved]`.
- **`TemperatureConfig(ushort[])`**
Constructor initializing from a `ushort[]` (indices 02 used; index 3 ignored).
- **`GetChannelsArray()` (int[])**
Returns array of enabled channel indices (015) based on `_channels` BitArray.
- **`GetMeasurementChannels()` (S6DBDiagnosticChannelList[])**
Returns list of `S6DBDiagnosticChannelList` enum values corresponding to enabled channels.
- **`GetChannelBitForDiagChannel(S6DBDiagnosticChannelList ch)` (TempLogChannelBits)**
Maps a diagnostic channel enum to its corresponding `TempLogChannelBits` enum value; throws `NullReferenceException` if not found.
### `TMNSConfig`
- **`TMNS_PCMSubFrameId` (uint, get/set)**
PCM sub-frame ID.
- **`TMNS_MsgId` (uint, get/set)**
TMNS message ID.
- **`TMNS_PCMMinorPerMajor` (uint, get/set)**
PCM minor-per-major setting.
- **`TMNS_TMATSPortNumber` (uint, get/set)**
TMATs port number.
- **`IENAUDP_PortNumber` (uint, get/set)**
IENA UDP source port number.
- **`TMNS5`, `TMNS6`, `TMNS7` (uint, get/set)**
Reserved fields.
- **`Fields` enum**
Defines field indices: `TMNS_PCMSubFrameID`, `TMNS_MsgId`, `TMNS_PCMMinorPerMajor`, `TMNS_TMATSPortNumber`, `IENAUDP_PortNumber`, `TMNS5`, `TMNS6`, `TMNS7`.
- **`TMNSConfig(uint[])`**
Constructor from `uint[]` (length truncated to 8 if longer; shorter arrays padded with zeros).
- **`TMNSConfig(string)`**
Constructor from comma-separated string (e.g., `"(1,2,3)"`); parses to `uint[]`.
- **`SetValue(Fields, uint)` / `GetValue(Fields)`**
Set/get field value by enum.
- **`ToUintArray()` (uint[])**
Returns a copy of the internal `uint[]`.
- **`ToCSVString()` (string)**
Returns config as `(x,y,z,...)` string.
- **`IsCh10(UDPStreamProfile)` (static bool)**
Returns `true` if profile is a CH10 variant.
- **`IsIENA(UDPStreamProfile)` (static bool)**
Returns `true` if profile is `IENA_PTYPE_STREAM`.
- **`IsTMNS(UDPStreamProfile)` (static bool)**
Returns `true` if profile is `TMNS_PCM_STANDARD` or `TMNS_PCM_SUPERCOM`.
- **`IsUART(UDPStreamProfile)` (static bool)**
Returns `true` if profile is `UART_STREAM`.
## 3. Invariants
- **`DiagnosticMessageRow`**: All three properties (`Field`, `Value`, `Verdict`) are non-null after construction (constructor assigns directly; no validation beyond constructor initialization).
- **`TCDiagnosticResult`**: `ChannelIndex` defaults to `0`; `Status` defaults to `DiagnosticStatus.Untested`; `ConnectionStatus` defaults to `ConnectionStatuses.NotTested`; `CurrentReading` defaults to `null`.
- **`CanDiagnostics`**: `ChannelIndex` defaults to `-1`; `Active` defaults to `false`; `Errors` is computed as `Overruns` if `ErrorFrame == 0`, else `1 + Overruns` (no negative values possible).
- **`TemperatureConfig`**:
- `_channels` BitArray is always 16 bits (initialized as `new BitArray(new[] { 0x00, 0x00 })`).
- `Reserved` is a compile-time constant `0` and not stored in the config array.
- `ToUShortArray()` always returns 4 elements: `[LogEnable, LogIntervalSec, Channels, 0]`.
- `GetChannelBitForDiagChannel()` throws `NullReferenceException` for unmapped channels (no fallback).
- **`TMNSConfig`**:
- Internal `_values` array is always exactly 8 elements (size derived from `Fields` enum).
- `ToUintArray()` returns a copy (not a reference).
- `ToCSVString()` always includes parentheses and exactly 8 comma-separated values.
## 4. Dependencies
### This module depends on:
- **`DTS.Common.Interface.DASFactory.Diagnostics`** (interfaces: `ITCDiagnosticResult`, `ICanDiagnosticResult`)
- **`DTS.Common.Interface.Sensors.AnalogDiagnostics`** (used in `TCDiagnosticResult`)
- **`DTS.Common.Enums.DASFactory`** (for `TempLogChannelBits`, `S6DBDiagnosticChannelList`, `DFConstantsAndEnums`)
- **`DTS.Common.Enums`** (for `UDPStreamProfile` in `TMNSConfig`)
- **`DTS.Common.Base`** (`BasePropertyChanged` base class for `TCDiagnosticResult` and `CanDiagnostics`)
### This module is depended upon by:
- **Diagnostic test runners** (e.g., CAN BIST, temperature logging, TMNS configuration tools) that instantiate and populate these classes.
- **UI/view layers** that bind to `TCDiagnosticResult`/`CanDiagnostics` via `INotifyPropertyChanged` (via `BasePropertyChanged`).
- **Configuration serialization/deserialization** (e.g., saving/loading `TemperatureConfig` or `TMNSConfig` to/from storage).
- **Diagnostic result aggregation** (e.g., combining `DiagnosticMessageRow` entries into test reports).
## 5. Gotchas
- **`TemperatureConfig.GetChannelBitForDiagChannel()` throws `NullReferenceException`** for unmapped channels—despite the method name suggesting a safe lookup, it does not use `TryGetValue`. Callers must ensure the channel is supported.
- **`TMNSConfig` string constructor is permissive**: Truncates or pads input to 8 fields; silently ignores non-parseable tokens (defaults to `0`).
- **`TemperatureConfig.Channels` setter uses `BitConverter.ToUInt16`**: Assumes little-endian byte order (standard on .NET Core/.NET 5+ but platform-dependent in older frameworks).
- **`CanDiagnostics.Errors` is computed, not stored**: Changes to `ErrorFrame` or `Overruns` trigger `OnPropertyChanged("Errors")`, but consumers must subscribe to `PropertyChanged` to react to this derived value.
- **`DiagnosticMessageRow` stores everything as `string`**: No type safety or parsing; callers must handle numeric/string interpretation.
- **`TMNSConfig` static methods (`IsCh10`, `IsIENA`, etc.) operate on `UDPStreamProfile` enum**: Behavior depends on complete enum coverage; missing cases in `switch` statements could cause incorrect results if new profiles are added.
- **`TCDiagnosticResult` and `CanDiagnostics` implement `INotifyPropertyChanged` via `BasePropertyChanged`**: Property changes are observable, but `Copy()` does *not* raise `PropertyChanged` events for the copied values—consumers may need to manually trigger updates.