# Configuration
|
|||
|
|
|
|||
|
|
### **Purpose**
|
|||
|
|
This `Configuration` class is responsible for applying hardware-specific voltage thresholds and configuration settings to a list of Data Acquisition System (DAS) units (`IDASCommunication` instances) prior to test execution or diagnostics. It orchestrates the configuration process by reading threshold values from a centralized settings store (`BatteryAndInputVoltageDefaults`), applying them to each DAS object, resetting hardware lines to a known state, and then invoking `ConfigurationService.SetConfiguration` to push the updated configuration to the hardware. It also ensures that the resulting configuration files are persisted locally per test by copying them from a global configuration directory to the current test’s directory.
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
### **Public Interface**
|
|||
|
|
|
|||
|
|
#### **`public void SetConfig(DataModel.TestTemplate currentTest, List<IDASCommunication> dasList, bool calledDuringDiagnostics, StatusHelpers.SetProgressValueDelegate setProgressFunction)`**
|
|||
|
|
- **Behavior**: Applies DAS-specific voltage thresholds (input and battery) based on hardware type, using different thresholds depending on whether the call is for diagnostics (`calledDuringDiagnostics == true`) or normal operation. After setting thresholds on each `IDASCommunication` object, it resets hardware lines via `ConfigurationService.ResetHardwareLines`, then calls `ConfigurationService.SetConfiguration` to commit the configuration to hardware. Progress is reported via `StatusHelpers.SetStatus2`. On success, it copies DAS and module configuration XML files to the test directory. Thread-safe via `lock` on `DASHardware.GetArmStatusLock`.
|
|||
|
|
- **Parameters**:
|
|||
|
|
- `currentTest`: The active test context; used to determine the destination directory for config file copying.
|
|||
|
|
- `dasList`: List of DAS units to configure.
|
|||
|
|
- `calledDuringDiagnostics`: If `true`, uses *diagnostic* thresholds (e.g., `BatteryHighDiagnosticsThreshold`); otherwise uses *armed* thresholds (e.g., `BatteryHighArmedThreshold`).
|
|||
|
|
- `setProgressFunction`: Delegate used to report progress during configuration.
|
|||
|
|
|
|||
|
|
#### **`public static DialogResult ErrorCallback(string errorString, string units)`**
|
|||
|
|
- **Behavior**: A static callback used by `ConfigurationService.SetConfiguration` to handle configuration errors. Logs the error via `APILogger.Log`, and currently returns `DialogResult.OK` (commented as a TODO: “Fix this”).
|
|||
|
|
- **Note**: Does not throw or re-raise the error; caller must rely on exception handling in `SetConfig` to detect failure.
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
### **Invariants**
|
|||
|
|
- **Thread Safety**: The entire `SetConfig` method body is guarded by `lock (DASHardware.GetArmStatusLock)`, ensuring only one configuration operation occurs at a time.
|
|||
|
|
- **Voltage Threshold Assignment**: For each `IDASCommunication das` in `dasList`, the following six properties are *always* set:
|
|||
|
|
- `MinimumValidInputVoltage`, `MaximumValidInputVoltage`
|
|||
|
|
- `MinimumValidBatteryVoltage`, `MaximumValidBatteryVoltage`
|
|||
|
|
- `BatteryHighVoltage`, `BatteryMediumVoltage`, `BatteryLowVoltage`
|
|||
|
|
- `InputHighVoltage`, `InputMediumVoltage`, `InputLowVoltage`
|
|||
|
|
The values are derived from `BatteryAndInputVoltageDefaults.InputAndBatterySettings.GetValue(type.ToString(), ...)`, where `type = das.GetHardwareType()`.
|
|||
|
|
- **Hardware Reset Precedes Configuration**: `ConfigurationService.ResetHardwareLines` is *always* called before `SetConfiguration`, per the comment: “setting the configuration checks the hardware lines so make sure we reset them prior to setting configuration.”
|
|||
|
|
- **Config File Copying**: After successful configuration, XML files for each DAS and its modules are copied from a global `Constants.DAS_CONFIGS` directory to `currentTest.TestDirectory`, overwriting existing files.
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
### **Dependencies**
|
|||
|
|
- **Imports/Usings**:
|
|||
|
|
- `DTS.Common.Interface.DASFactory.IDASCommunication`: Interface for DAS communication objects.
|
|||
|
|
- `DTS.DASLib.Service.ConfigurationService`: Core service used to perform hardware reset and configuration.
|
|||
|
|
- `DTS.Common.DataModel.Common.StatusHelpers`: Provides `SetStatus2` and `SetProgressValueDelegate`.
|
|||
|
|
- `DTS.Common.Utilities.Logging.APILogger`: Used for logging errors and exceptions.
|
|||
|
|
- `DTS.Common.DataModel.Classes.TSRAIRGo.TSRAIRGoStatus`: Defines `StatusTypes.UPDATING_DAS_CONFIG`.
|
|||
|
|
- `DTS.Common.Enums.TSRAIRGo`: Enum namespace (used via `TSRAIRGoStatus`).
|
|||
|
|
- `System.Windows.Forms.DialogResult`: Used in `ErrorCallback`.
|
|||
|
|
- `DTS.Common.DataModel.Common.DataModel.BatteryAndInputVoltageDefaults`: Static source of voltage thresholds.
|
|||
|
|
- `DTS.Common.Constants`: Defines `DAS_CONFIGS` (directory name).
|
|||
|
|
- `DTS.Common.SerializedSettings`: Provides `MaxAAFRate_TDAS`, `MaxAAFRate_G5`, and `GetDefaultDSP()`.
|
|||
|
|
|
|||
|
|
- **External Dependencies**:
|
|||
|
|
- `DASHardware.GetArmStatusLock`: A static lock object used for synchronization.
|
|||
|
|
- `Environment.CurrentDirectory`: Base path for global config directory.
|
|||
|
|
- File system: Requires existence of `DAS_CONFIGS` directory (via `Constants.DAS_CONFIGS`) and read access to XML files.
|
|||
|
|
|
|||
|
|
- **Called By**: Presumably invoked by higher-level test orchestration logic (e.g., before test start or diagnostics run). Not referenced in source, but usage is implied by test context (`currentTest`) and progress reporting.
|
|||
|
|
|
|||
|
|
---
|
|||
|
|
|
|||
|
|
### **Gotchas**
|
|||
|
|
- **Hardcoded Threshold Keys**: Threshold keys (e.g., `"BatteryHighDiagnosticsThreshold"`) are string literals; no compile-time safety. A mismatch in key names in `BatteryAndInputVoltageDefaults` will result in default fallback values (via `GetValue`’s second parameter), potentially leading to incorrect thresholds.
|
|||
|
|
- **Blocking Wait Loop**: The `while (!done.WaitOne(50, false)) { elapsed += 50; }` loop is a polling-based wait. While functional, it may be inefficient or mask timing issues; no timeout is enforced beyond the loop’s implicit duration (no `elapsed`-based timeout check).
|
|||
|
|
- **`ErrorCallback` Does Not Propagate Errors**: Returns `DialogResult.OK` unconditionally; actual failure detection relies on exceptions thrown in `SetConfig` or `SetConfiguration`. If `SetConfiguration` fails silently (e.g., via `CallbackStatus.Failure` without throwing), this may go unnoticed.
|
|||
|
|
- **Assumes `das.DASInfo` is `InfoResult`**: In `CopyGlobalConfigsToLocalFolder`, `((InfoResult)das.DASInfo).OwningDAS` and `module.SerialNumber` are cast without type checking. If `das.DASInfo` is not an `InfoResult`, this will throw at runtime.
|
|||
|
|
- **No Validation of `dasList`**: `SetConfig` does not check for null or empty `dasList`, which could lead to no-op or unexpected behavior.
|
|||
|
|
- **`AggregateProgress = false`**: Indicates per-DAS progress reporting is expected, but the callback logic uses `cbd.Target` (a DAS instance) to report progress—this is consistent, but the setting may be easy to overlook.
|
|||
|
|
- **Commented TODO**: `//Fix this` next to `return DialogResult.OK;` in `ErrorCallback` indicates known technical debt.
|