source_files:
|
||
|
|
- DataPRO/IService/Classes/Diagnostics/OptimizationValues.cs
|
||
|
|
- DataPRO/IService/Classes/Diagnostics/DiagnosticActions.cs
|
||
|
|
- DataPRO/IService/Classes/Diagnostics/DiagnosticsResultActions.cs
|
||
|
|
- DataPRO/IService/Classes/Diagnostics/DiagnosticsResult.cs
|
||
|
|
generated_at: "2026-04-17T15:38:51.449636+00:00"
|
||
|
|
model: "zai-org/GLM-5-FP8"
|
||
|
|
schema_version: 1
|
||
|
|
sha256: "34ce6d811e6f9b1a"
|
||
|
|
---
|
||
|
|
|
||
|
|
# Diagnostics Module Documentation
|
||
|
|
|
||
|
|
## 1. Purpose
|
||
|
|
|
||
|
|
This module provides data structures and operations for managing diagnostic tests and results for Data Acquisition System (DAS) channels. It enables pre-recording validation of sensor configurations by measuring excitation voltages, offsets, noise floors, shunt deflections, bridge resistance, and squib firing characteristics. The module bridges in-memory diagnostic state with persistent database storage, supporting analog input channels, digital input channels, and output squib channels.
|
||
|
|
|
||
|
|
---
|
||
|
|
|
||
|
|
## 2. Public Interface
|
||
|
|
|
||
|
|
### `OptimizationValues` (Class)
|
||
|
|
**Namespace:** `DTS.DASLib.Service.Classes.Diagnostics`
|
||
|
|
**Implements:** `IOptimizationValues`
|
||
|
|
|
||
|
|
| Property | Type | Description |
|
||
|
|
|----------|------|-------------|
|
||
|
|
| `TransferSpeed` | `float` | Gets or sets the transfer speed value. |
|
||
|
|
|
||
|
|
---
|
||
|
|
|
||
|
|
### `DiagnosticsActions` (Class)
|
||
|
|
**Namespace:** `DTS.DASLib.Service`
|
||
|
|
**Implements:** `IDiagnosticActions`
|
||
|
|
|
||
|
|
Holds instructions for diagnosing a single DAS channel.
|
||
|
|
|
||
|
|
#### Properties
|
||
|
|
|
||
|
|
| Property | Type | Default | Description |
|
||
|
|
|----------|------|---------|-------------|
|
||
|
|
| `DASChannelNumber` | `int` | `0` | The DAS channel number for these diagnostic instructions. |
|
||
|
|
| `MeasureExcitation` | `bool` | `false` | Whether to measure excitation voltage applied to the sensor. |
|
||
|
|
| `MeasureOffset` | `bool` | `false` | Whether to measure the sensor's offset from zero. |
|
||
|
|
| `CheckDigitalState` | `bool` | `false` | Whether to check open/closed/low/high state of a digital input channel. |
|
||
|
|
| `MeasureInternalOffset` | `bool` | `false` | Whether to measure internal offset. |
|
||
|
|
| `RemoveOffset` | `bool` | `false` | Whether firmware should compensate for sensor offset. |
|
||
|
|
| `MeasureNoise` | `bool` | `false` | Whether to measure noise floor as percentage of full scale. |
|
||
|
|
| `PerformShuntCheck` | `bool` | `false` | Whether to perform an emulated shunt check. |
|
||
|
|
| `SquibFireCheck` | `bool` | `false` | Whether to run a squib fire check on the channel. |
|
||
|
|
| `PerformVoltageInsertCheck` | `bool` | `false` | Whether to perform a voltage insertion gain check (SLICE Pro). |
|
||
|
|
| `PerformCalSignalCheck` | `bool` | `false` | Whether to perform a calibration signal check. |
|
||
|
|
| `MeasureBridgeResistance` | `bool` | `false` | Whether to measure the resistance of the bridge. |
|
||
|
|
|
||
|
|
#### Methods
|
||
|
|
|
||
|
|
```csharp
|
||
|
|
public DiagnosticsActions()
|
||
|
|
```
|
||
|
|
Initializes a new instance with all diagnostic actions disabled and `DASChannelNumber` set to 0.
|
||
|
|
|
||
|
|
```csharp
|
||
|
|
public bool AllActionsDisabled()
|
||
|
|
```
|
||
|
|
Returns `true` if all diagnostic actions are disabled; otherwise `false`.
|
||
|
|
|
||
|
|
```csharp
|
||
|
|
public static void SetChannelDiagnosticActions(IDASCommunication unit, IDiagnosticActions[] actions, bool setInDb)
|
||
|
|
```
|
||
|
|
Assigns the diagnostic actions array to `unit.ChannelDiagnostics`. If `setInDb` is `true` and the database is connected, clears all existing diagnostic actions for the unit and inserts the new actions into the database.
|
||
|
|
|
||
|
|
---
|
||
|
|
|
||
|
|
### `DiagnosticsResultActions` (Static Class)
|
||
|
|
**Namespace:** `DTS.DASLib.Service.Classes.Diagnostics`
|
||
|
|
|
||
|
|
Provides static methods for managing diagnostic results on DAS units.
|
||
|
|
|
||
|
|
#### Methods
|
||
|
|
|
||
|
|
```csharp
|
||
|
|
public static void ClearChannelDiagnosticsResults(IDASCommunication unit, bool bClearDb = true)
|
||
|
|
```
|
||
|
|
Clears `unit.ChannelDiagnosticsResults` and `unit.ChannelDiagnostics` by initializing them to empty arrays. If `bClearDb` is `true` and the database is connected, clears existing diagnostics from the database for the unit.
|
||
|
|
|
||
|
|
```csharp
|
||
|
|
public static void SetChannelDiagnosticsResults(IDASCommunication unit, IDiagnosticResult[] results, bool setInDb)
|
||
|
|
```
|
||
|
|
Assigns `results` to `unit.ChannelDiagnosticsResults`. If `setInDb` is `true` and the database is connected, iterates through results and inserts them into the database based on channel type:
|
||
|
|
- `AnalogInputDASChannel` with `DigitalInputChannel == true` → `InsertDiagnosticsResultDigital`
|
||
|
|
- `AnalogInputDASChannel` with `DigitalInputChannel == false` → `InsertDiagnosticsResultAnalog`
|
||
|
|
- `OutputSquibChannel` → `InsertDiagnosticsResultsSquib`
|
||
|
|
|
||
|
|
---
|
||
|
|
|
||
|
|
### `DiagnosticsResult` (Class)
|
||
|
|
**Namespace:** `DTS.DASLib.Service`
|
||
|
|
**Implements:** `IDiagnosticResult`
|
||
|
|
|
||
|
|
Holds diagnostic results for a single DAS channel.
|
||
|
|
|
||
|
|
#### Key Properties
|
||
|
|
|
||
|
|
| Property | Type | Default | Description |
|
||
|
|
|----------|------|---------|-------------|
|
||
|
|
| `DASChannelNumber` | `int` | — | The channel number from which diagnostics are returned. |
|
||
|
|
| `EventNumber` | `int` | — | The event number this diagnostic is relevant for. |
|
||
|
|
| `ScalefactorMilliVoltsPerADC` | `double` | `1` | Scale factor to convert raw ADC values to millivolts. |
|
||
|
|
| `ScalefactorEngineeringUnitsPerADC` | `double` | `1` | Scale factor to convert ADC values to engineering units. |
|
||
|
|
| `ExpectedExcitationMilliVolts` | `double` | — | Factory excitation value (mandatory). |
|
||
|
|
| `MeasuredExcitationMilliVolts` | `double?` | — | Measured excitation voltage in mV. |
|
||
|
|
| `NegativeExcitation` | `bool` | — | Flag indicating if measured excitation was negative. |
|
||
|
|
| `MeasuredOffsetMilliVolts` | `double?` | — | Sensor offset from zero in mV. |
|
||
|
|
| `MeasuredInternalOffsetMilliVolts` | `double?` | — | Measured internal offset in mV. |
|
||
|
|
| `AutoZeroPercentDeviation` | `double?` | — | Deviation from zero during auto-zero (stored as absolute value). |
|
||
|
|
| `FinalOffsetADC` | `short?` | — | Offset remaining after offset removal. |
|
||
|
|
| `RemovedOffsetADC` | `int?` | — | Amount of offset removed. |
|
||
|
|
| `RemovedInternalOffsetADC
|