ALTER PROCEDURE [dbo].[sp_SensorsSquibGet]
@ID INT = NULL,
@SerialNumber NVARCHAR (50) = null,
@EID NVARCHAR (50) = NULL
AS
BEGIN
IF(@ID IS NULL )
BEGIN
IF NULLIF(@SerialNumber, '') IS NULL
BEGIN
IF (@EID IS NULL )
BEGIN
SELECT B.id, B.SerialNumber, A.ArticleId, A.BypassCurrentFilter, A.BypassCurrentFilter, A.BypassVoltageFilter, A.DelayMS, A.DurationMS, A.FireMode, A.IsoChannelName, A.IsoCode, A.LastModified, A.LastModifiedBy, A.LimitDuration, A.DefineDelayInTest, A.MeasurementType, A.SquibOutputCurrent, A.SquibToleranceHigh, A.SquibToleranceLow, A.UserChannelName, A.UserCode, A.UserTags, A.UserValue1, A.UserValue2, A.UserValue3, A.Version, A.Broken, A.DoNotUse FROM SensorsSquib AS A INNER JOIN Sensors AS B ON A.SensorId = B.id INNER JOIN [dbo].[SensorsType] AS C ON B.SensorType=C.TypeId WHERE C.SensorType='Squib'
END
ELSE
BEGIN
SELECT B.id, B.SerialNumber, A.ArticleId, A.BypassCurrentFilter, A.BypassCurrentFilter, A.BypassVoltageFilter, A.DelayMS, A.DurationMS, A.FireMode, A.IsoChannelName, A.IsoCode, A.LastModified, A.LastModifiedBy, A.LimitDuration, A.DefineDelayInTest, A.MeasurementType, A.SquibOutputCurrent, A.SquibToleranceHigh, A.SquibToleranceLow, A.UserChannelName, A.UserCode, A.UserTags, A.UserValue1, A.UserValue2, A.UserValue3, A.Version, A.Broken, A.DoNotUse FROM SensorsSquib AS A INNER JOIN Sensors AS B ON A.SensorId = B.id INNER JOIN [dbo].[SensorsType] AS C ON B.SensorType=C.TypeId WHERE C.SensorType='Squib' AND A.ArticleId=@EID
END
END
ELSE
BEGIN
SELECT B.id, B.SerialNumber, A.ArticleId, A.BypassCurrentFilter, A.BypassCurrentFilter, A.BypassVoltageFilter, A.DelayMS, A.DurationMS, A.FireMode, A.IsoChannelName, A.IsoCode, A.LastModified, A.LastModifiedBy, A.LimitDuration, A.DefineDelayInTest, A.MeasurementType, A.SquibOutputCurrent, A.SquibToleranceHigh, A.SquibToleranceLow, A.UserChannelName, A.UserCode, A.UserTags, A.UserValue1, A.UserValue2, A.UserValue3, A.Version, A.Broken, A.DoNotUse FROM SensorsSquib AS A INNER JOIN Sensors AS B ON A.SensorId = B.id INNER JOIN [dbo].[SensorsType] AS C ON B.SensorType=C.TypeId WHERE C.SensorType='Squib' AND B.SerialNumber=@SerialNumber
END
END
ELSE
BEGIN
SELECT B.id, B.SerialNumber, A.ArticleId, A.BypassCurrentFilter, A.BypassCurrentFilter, A.BypassVoltageFilter, A.DelayMS, A.DurationMS, A.FireMode, A.IsoChannelName, A.IsoCode, A.LastModified, A.LastModifiedBy, A.LimitDuration, A.DefineDelayInTest, A.MeasurementType, A.SquibOutputCurrent, A.SquibToleranceHigh, A.SquibToleranceLow, A.UserChannelName, A.UserCode, A.UserTags, A.UserValue1, A.UserValue2, A.UserValue3, A.Version, A.Broken, A.DoNotUse FROM SensorsSquib AS A INNER JOIN Sensors AS B ON A.SensorId = B.id INNER JOIN [dbo].[SensorsType] AS C ON B.SensorType=C.TypeId WHERE C.SensorType='Squib' AND B.id=@ID
END
END